15
Specifications
Description, Specifications, Installation, and Operation Manual
Federal Signal
www.fedsig.com
DTMF
String length
Mark/Space timing:
Decoder Minimum
Decoder Maximum
Encoder
Space between Stacked codes
All timings in milliseconds
3-12 standard DTMF characters
50 ms/50 ms (below 50/50 consult factory)
800 ms total mark/space timing per code
100 ms/100 ms mark/space timing
minimum 1.25 seconds
AFSK
Baud rate
Modem type
Mark frequency
Space frequency
Error checking
1200 bps
MSK (minimal shift key)
1200 Hz
1800 Hz
16 bit CRC
EAS
Supports standard EAS codes and wildcards
POCSAG
Supports Binary frequency shift keying
512 Baud numeric messages
Decode Sensitivity
18 dB SINAD for tone (except with CTCSS
tones > 200 Hz and decode tones < 400 Hz)
and 21 dB SINAD for MSK, EAS, POCSAG
and DTMF with 50 ms/50 ms or greater
timing
Two Way Formats
Federal Packet Digital and DTMF
Table 14 Environmental and Physical
Operating temperature range
-22°F to +150°F (-30°C to + 65°C)
Humidity
0-95%, non-condensing
Control cabinet (H x W x D)
20.36 x 16.30 x 6.62 inches
(51.7 x 41.4 x 16.8 cm)
UVRI-B (Weight without radio)
41.4 lb (18.8 kg)
Net Shipping Weight
45.4 lb (20.6 kg)
UVRI-BH and UVRI-BU (Weight with radio) 44.6 lb (20.2 kg)
Net Shipping Weight
48.6 lb (22.0 kg)
UVRI-B100 (Weight with amplifier)
44.8 lb (20.3 kg)
Net Shipping Weight
48.8 lb (22.1 kg)
UVRI-BH100 and UVRI-BU100
(Weight with radio and amplifier)
48.0 lb (21.8 kg)
Net Shipping Weight
52.0 lb (23.6 kg)