B. Fuse Replacement.

To replace the fuse, proceed as follows:

1.  The fuse is positioned on the component side of the P.C. board, mounted in fuse clips. 

For easy removal, pry one end of the fuse out of the clip with an insulated-handled screw-

driver.

2.  Replace the fuse with one of the same rating only. The DC 131ST units use a 5 A, 32 V, 

auto-type fuse (Federal Part No. K148A142-03). The 120 Vac units use a 1 A, 250 V, 

slow-blow GMC-type fuse (Federal Signal Part No. K148A155-01).

3.  Reassemble the light and test for proper operation.

C. Service.

The Federal Signal factory will service your equipment or provide technical assistance with 

any problems that cannot be handled locally.
Any units returned to Federal Signal for service, inspection, or repair must be accompanied 

by a Return Material Authorization. This R.M.A. can be obtained from the local Distributor or 

Manufacturer’s Representative.
At this time a brief explanation of the service requested, or the nature of the malfunction, 

should be provided.
Address all communications and shipments to:

D. Replacement Parts.

Description 

Part Number

Dome, Clear* 

K8422B428

Dome, Amber* 

K8422B428-01

Dome, Blue* 

K8422B428-02

Dome, Green*  

K8422B428-03

Dome, Red* 

K8422B428-04

Strobe Tube 

K8107178

Surface-Mount Kit 

K8444A211

*Includes dome gasket

E.  Optional Accessories.

Description 

Part Number

Corner Bracket 

LCMB2

Wall Bracket 

LWMB2

Surface Mount 

K8444A211

-3-

Industrial Systems

2645 Federal Signal Drive • University Park, IL 60484-3167

Tel.: 1-708-534-4756 • 1-877-289-3246 • Fax: 1-708-534-4852

www.federalsignal-indust.com • www.fs-isys.com

Содержание STARFIRE 131ST

Страница 1: ...ET 131DST 24V CC ET 120V CA MODELOS 131ST y 131DST HOJA DE INSTRUCCIONES PARA LUZ DE DESTELLO STARFIRE 24VCC Y 120VCA MODELOS FEDERAL 131ST Y 131DST MODELS 131ST and 131DST INSTRUCTION SHEET FOR FEDE...

Страница 2: ...sheet to all personnel Establish a procedure to routinely check the light system for proper activation and operation Failure to follow all safety precautions and instructions may result in property da...

Страница 3: ...ce to maintenance personnel should NOT be obscured in any way Ensure that the nameplate remains readable when the housing s exterior is painted Failure to follow all safety precautions and instruction...

Страница 4: ...returned to Federal Signal for service inspection or repair must be accompanied by a Return Material Authorization This R M A can be obtained from the local Distributor or Manufacturer s Representati...

Страница 5: ...revent misapplication of a visual signal appliance Listed to UL1638 UL determined it is the manufacturer s responsibility to warn the installer in the field and Authority Having Jurisdiction AHJ of wh...

Страница 6: ...B Manguito hembra 1 2 N P T C Conductor verde a tierra luces CA unicamente D Conectores de alimentaci n E Tuerca de seguridad conducto F Carcasa ligera Fran ais A Plaque de base B Douille femelle 1 2...

Страница 7: ...8107178 Espa ol A El tubo de destellos luminosos usado tiende a decolorarse en las areas senaladas y debe ser substituido B Tubo de destellos luminosos nuevo K8107178 Fran ais A Un tube clignotant use...

Отзывы: