ed to position one “Center” to position two and “Right to
position three. The “Fast” (WHT/GRY) input will cause
the SignalMaster to operate at twice the normal speed,
when 12VDC is applied to the input.
B.
SignalMaster External Controller.
1.
See figure 3-5. Ensure that jumpers JP2
& JP7 are installed as indicated.
2.
Refer to table 3-1 and connect the Sig-
nalMaster input wires to the corresponding connections
for the SS2000/SM, SMC16 and SMC56 SignalMaster
controllers.
3-4. PROGRAMMING LED FLASH PATTERNS.
There are three lightbar modes that can be pro-
grammed by the user, via three control input wires.
There are also six available LED flash patterns:
•
Random
•
Quad Flash alternating 75FPM
•
Single Flash alternating 75FPM
•
Alternate Flash POD’s 1&7 90FPM rear only
•
Alternate Flash POD’s 1&7 90FPM front and
rear
•
Alternate Flash POD’s 1&7 with POD 4
90FPM rear only
Three default patterns are assigned to operate in
slide switch positions 1, 2, and 3. They are as follows:
•
WHT/ORG - Mode #1 – Single flash
•
RED - Mode #2 – Quad flash
•
WHT/RED - Mode #3 – Random
To change a flash pattern assigned to a slide switch
perform the following:
A. Activate lightbar in the desired slide switch
position. The bar will flash in the current pattern.
B.
Momentarily apply 12VDC to the program
input (WHT/BLK). The LED flash pattern will advance
to the next available pattern and the end LED module
in POD #1 will flash the selected pattern number. The
lightbar will stop momentarily, then operate in the
selected pattern. Each time 12VDC is momentarily ap-
plied the pattern number will advance. When the last
available pattern number is reached, the next momen-
tary application of 12 VDC will select the first available
pattern.
C.
If patterns assigned to the other mode inputs
are to be changed, apply 12VDC to the desired mode in-
put and repeat the above steps.
3-5. PROGRAMMING SMART POD PATTERNS.
There are three Smart Pod program inputs plus an
OFF position that can be assigned to a slide switch posi-
tion.
1.
Off
2.
P1
3.
P2
4.
P3
The Smart Pods are programmable on two levels.
First, each of the program inputs, i.e., P1, P2, and P3,
can be set to do one of eight available patterns. See fig-
ure 3-6. These patterns are selected using dip switches
located on the Smart Pod Controller board. Refer to
-4-
1
6
O
N
WL TD 1/2 P3C P3B P3A
-
+
-
R37
R28
J6
R10
U4
R36
R26
D3
R27
F2
F3
+
J5
R9
U3
1
J4
U2
R25
R35
D2
8
R12
1
J3
U1
C11
C15
P3A
S1
R34
2
R53
D6
1
R52
D5 R40
2005325A-
UNIVERSITY PARK,IL
P1B
P2A
P1C
P1A
R39
P2C
S2
1
P2B
1 U6
RN2
D11
C16
Q5
RN1
Q6
C17
C18
FEDERAL SIGNAL CORP.
1
1
7
R8
R7
R11
R20
R6
R4 R5
R17R18R19
P3B
P3C
WL
1/
2
C7
C5 C6
C13
TD
C8
C9
R3
R1 R2
R13 R14R15
C4
C2 C3
C12
Q11
R33
R16
F1
J1
J2
BATT-
H1
C1
1
L1
C14
J8
Q4
8
1
R32
L4
R31
R23
R24
L5
F4
D1
H2
BATT+
D8
D9
R51
C26 D7
C19
+
C22
R38
U5
R50
R41
U7
C25
D4
C24
C23
C20
C21
L9
Q10
R49
R44
L8
R45
+
Y1
L3
R30
R22
10
Q1
R29
R21
Q2
J7
Q9
R43
L7
Q7
L6
R42
R47
Q8
R46
L2
R48
Q3
D10
C10
S1
P1B
P2A
P1C
P1A
P2C
S2
P2B
6 POS SWITCH
290A5310-06
Figure 3-6.
Содержание SMART VECTOR SL
Страница 12: ......