I.  INSTALLATION

WARNING

Failure to follow all safety precautions and instructions may result in property damage, serious injury, or 

death to you or others.

SAFETY MESSAGE TO INSTALLERS

Peoples lives depend on your safe installation of our products. It is important to follow all instructions 
shipped with the products.

This device is to be installed by a trained electrician who is thoroughly familiar with the applicable 
National Electric Code and will follow the NEC guidelines as well as local codes.

The selection of the mounting location for the device, its controls and the routing of the wiring are to be 
accomplished under the direction of the Facilities Engineer and the Safety Engineer. In addition, listed 
below are some other important safety instructions and precautions you should follow:

• 

Read and understand all instructions before installing or operating this equipment.

• 

Do not connect this unit to the system when power is on.

• 

Optimum sound distribution will be severely reduced if any objects are in front of the siren. You should 
ensure that the front of the siren is clear of any obstructions.

• 

All effective signaling sirens produce loud sounds, which may cause, in certain situations, permanent 
hearing loss. They should be installed far enough away from potential listeners to limit their exposure 
while still maintaining their effectiveness. The OSHA Code of Federal Regulations 1910.95 provides 
guidelines which may be used regarding permissible noise exposure levels.

• 

After installation, ensure that all mounting bolts are properly tightened.

• 

After installation, test the emergency warning system to ensure proper operation.

• 

Show these instructions to your Safety Engineer and then file them in a safe place and refer to them 
when maintaining and/or reinstalling the unit.

• 

Establish a procedure to routinely check the signaling system for proper activation and operation.

 

A. GENERAL

The Models A and L sirens are intended for general signaling applications. Then have NEMA 3R 
enclosures which are suitable for indoor or outdoor use, providing a degree of protection from rain, 
sleet and damage from external ice formation. The Model A is intended to operate on 120 volts AC 
or DC. The 120 volt and 240 volt Model L sirens are also intended to operate on AC or DC. The 
Model A siren is Underwriters Laboratories Listed as an audible signal (File E4813) for use in USA 
(Category UCST) or Canada (Category UCST7) and is also CSA Certified for use in Canada (Class 
4812 04).

 

B. UNPACKING

After unpacking the unit, examine it for damage that may have occurred in transit. If the equipment 
has been damaged, do not attempt to install or operate it, file a claim immediately with the carrier 
stating the extent of the damage. Carefully check all envelopes, shipping labels and tags before 
removing or destroying them.

-1-

Содержание Siren A

Страница 1: ...256996F REV F 613 Printed in U S A Siren Models A L Installation and Maintenance Manual français page 5 español página 9 ...

Страница 2: ......

Страница 3: ...ntial listeners to limit their exposure while still maintaining their effectiveness The OSHA Code of Federal Regulations 1910 95 provides guidelines which may be used regarding permissible noise exposure levels After installation ensure that all mounting bolts are properly tightened After installation test the emergency warning system to ensure proper operation Show these instructions to your Safe...

Страница 4: ...nch threaded conduit opening and 18 inch field wiring leads The user supplied electrical box should be mounted as close as possible to the siren using suitable flexible conduit for connecting them 1 When the Model A siren is to be connected to AC power its black lead should be connected to the phase lead its white lead to the neutral lead and its green lead to ground When the Model A is to be conn...

Страница 5: ...e this fact and take steps to ensure it is achieving the desired effect II MAINTENANCE Other than cleaning no regularly scheduled maintenance is required To ensure unit is operating properly it should be tested at regularly scheduled intervals In the event repair is required listed below are some safety instructions and precautions you should follow WARNING Failure to follow all safety precautions...

Страница 6: ... Material Authorization This R M A can be obtained from the local Distributor or Manufacturer s Representative At this time a brief explanation of the service requested or the nature of the malfunction should be given Address all communications and shipments to Industrial Systems 2645 Federal Signal Drive University Park IL 60484 3167 Tel 1 708 534 4756 1 877 289 3246 Fax 1 708 534 4852 www federa...

Страница 7: ...ent entraîner dans certaines situations une perte permanente de l ouïe Elles doivent être installées suffisamment loin des auditeurs potentiels afin de limiter l exposition de ces derniers tout en restant efficaces Le Code des réglementations fédérales OSHA 1910 95 fournit des directives qui peuvent être utilisées en ce qui concerne les niveaux permis d exposition au bruit Après l installation s a...

Страница 8: ... fixée sur la surface desserrer les écrous hexagonaux sur les côtés de la sirène et régler le dispositif sur la position désirée Resserrer les écrous hexagonaux REMARQUE S assurer qu aucun objet ne bloque le projecteur de la sirène D BRANCHEMENTS ÉLECTRIQUES AVERTISSEMENT Ne pas effectuer de raccordement si les câbles d alimentation sont sous tension REMARQUE LE RACCORDEMENT DES CÂBLES DE LA SIRÈN...

Страница 9: ...nstructions et de précautions de sécurité importantes à respecter Il est important que vous lisiez et que vous compreniez toutes les instructions avant d utiliser ce système Les sirènes efficaces produisent un son puissant qui peut entraîner dans certaines situations une perte permanente de l ouïe Vous devriez prendre les précautions nécessaires et notamment vous assurer par exemple que le niveau ...

Страница 10: ...en ne doit pas être obscurcie si l extérieur des enceintes est peint III ENTRETIEN L usine de Federal Signal procédera à l entretien de votre équipement ou vous fournira une assistance technique pour tout problème qui ne peut être résolu sur place Tous les appareils retournés à Federal Signal pour entretien inspection ou réparation doivent être accompagnés d une autorisation de retour du produit V...

Страница 11: ...audición Deben ser instaladas a una distancia suficiente de las personas que potencialmente puedan escucharlas para limitar su exposición y al mismo tiempo mantener su efectividad El Código de Reglamentaciones Federales 1910 95 de la Administración de Seguridad y Salud Ocupacional proporciona lineamientos que pueden usarse con respecto a los niveles permitidos de exposición al ruido Después de la ...

Страница 12: ...aje Una vez que la sirena está sujeta firmemente a la superficie afloje las tuercas hexagonales en los lados de la sirena y ajuste la unidad a la posición deseada Vuelva a ajustar las tuercas hexagonales NOTA Asegúrese de que nada obstruya el proyector de la sirena D CONEXIONES ELÉCTRICAS ADVERTENCIA No conecte si los cables de alimentación están energizados NOTA LA CONEXIÓN DE LOS CABLES DE ALIME...

Страница 13: ...inuación se incluyen algunas instrucciones y precauciones importantes de seguridad que debe seguir Es importante que lea y comprenda todas las instrucciones antes de poner en funcionamiento este sistema Todas las sirenas efectivas producen sonidos fuertes que pueden ocasionar en ciertas situaciones la pérdida permanente de la audición Debe tomar precauciones apropiadas tales como asegurar que no s...

Страница 14: ... para el personal de mantenimiento no debe quedar oculta III SERVICIO Federal Signal realizará las tareas de servicio de sus equipos o proporcionará asistencia técnica con los problemas que no se puedan manejar a nivel local Las unidades devueltas a Federal Signal para servicio inspección o reparación deben acompañarse de una Autorización de devolución de material Esta autorización de devolución d...

Страница 15: ......

Страница 16: ...Industrial Systems 2645 Federal Signal Drive University Park IL 60484 3167 Tel 1 708 534 4756 1 877 289 3246 Fax 1 708 534 4852 www federalsignal indust com www fs isys com 2013 Federal Signal Corp ...

Страница 17: ......

Отзывы: