should be long enough to route from the light assembly to 

the right, and left, turn signal lamp sockets.

 

 

 

b.  Remove and retain the three screws 

which secure the light assembly end plate at the cable exit 

end.

 

 

 

c.  Remove the end plate and slide the lens 

mounting plate out about six-inches.

When connecting the right angle terminals to 

connectors H1 and H2, support the circuit board 

to avoid breaking the terminals or cracking the 

printed circuit board.

 

 

 

d.  See figure 3. Connect the two right angle 

terminals to connectors H1 and H2. Note which wire is at-

tached to H1 and to H2. 

 

 

 

e.  Slide the lens mounting plate into the 

extrusion. Route the 22-gauge wires through the grommet. 

Secure the end plate on the light assembly using the previ-

ously removed screws.

 

 

 

f.  Route each 22-gauge wire to the appropri-

ate turn signal lamp socket. Connect the wire from H2 to 

the right turn signal lamp power wire. Connect the wire 

from H1 to the left turn signal lamp power wire.

 

D. 

Inspection and Final Installation.

 

 

1.  Ensure that there are no loose wire strands or 

other bare wires which may cause a short circuit. Also, all 

wires must be protected from any sharp edges which could 

eventually cut through the insulation.

 

 

2.  Connect the 14-gauge red wire to the (+) posi-

tive terminal of the battery using an in-line, user-supplied 

fuseholder and 25A fuse. Locate the fuse as near the bat-

tery as possible to protect the entire length of wire.

NOTE

All directional lamps will illuminate simultaneous-

ly if the power supply leads are reversed. Correct 

the wiring before proceeding.

 

 

3.  Read and understand paragraph IV OPERA-

TION, and test for proper operation of all functions.

 

 

 

c.  Connect the terminals on the switch as 

shown in figure 2.

 

 

3.  Illuminated Power Switch.

Improper wiring of the illuminated switch feature 

will result in printed circuit board damage. Ensure 

that the chassis ground lead is connected to the 

gold (pin #3) terminal and that the unterminated 

end of the lead is connected to a known good chas-

sis ground.

 

 

 

a.  See figure 2. Connect the right angle 

terminal on the switch bracket ground lead to the gold (pin 

#3) terminal of the on-off switch.

 

 

 

b.  Route the unterminated end of the ground 

lead to a known good chassis ground. Cut the lead to length 

and crimp the supplied ring terminal on the lead. 

NOTE

If necessary, additional 18-gauge wire may be 

spliced to the ground lead.

 

 

 

c.  Secure the lead to the chassis ground with 

a user-supplied screw.

 

 

4.  Turn Signal Connections (optional).

 

 

 

a.  Crimp the two right angle terminals on 

one end of two user-supplied 22-gauge wires. The wires 

-3-

Figure 2.

NOTE: TWO WIRES ARE 

CRIMPED IN ONE TERMINAL

NOTE: MATING FEMALE TERMINALS ARE CRIMPED

ON WIRES BEFORE CONNECTING TO SWITCHES.

CONTROL CABLE
ASSEMBLY

BLACK

RED

290A2885B

WHITE

SWITCH BRACKET

REAR VIEW

JUMPER WIRE FROM

INSTALLATION KIT

GREEN

RED

GOLD

TERMINAL

OFF-ON

SWITCH

CHASSIS GROUND

HAZARD

SWITCH

3

2

1

3

2

1

CAUTION

IMPROPER WIRING OF THE ILLUMINATED SWITCH FEATURE

WILL RESULT IN P.C.B. DAMAGE.  ENSURE THAT THE CHASSIS GROUND

LEAD IS CONNECTED TO THE GOLD (PIN #3) TERMINAL AND THAT

THE UNTERMINATED END OF THE LEAD IS CONNECTED

TO A KNOWN GOOD CHASSIS GROUND.