![Federal Signal Corporation SIGNALMASTER SM518A Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/federal-signal-corporation/signalmaster-sm518a/signalmaster-sm518a_instruction-sheet_3931566003.webp)
should be long enough to route from the light assembly to
the right, and left, turn signal lamp sockets.
b. Remove and retain the three screws
which secure the light assembly end plate at the cable exit
end.
c. Remove the end plate and slide the lens
mounting plate out about six-inches.
When connecting the right angle terminals to
connectors H1 and H2, support the circuit board
to avoid breaking the terminals or cracking the
printed circuit board.
d. See figure 3. Connect the two right angle
terminals to connectors H1 and H2. Note which wire is at-
tached to H1 and to H2.
e. Slide the lens mounting plate into the
extrusion. Route the 22-gauge wires through the grommet.
Secure the end plate on the light assembly using the previ-
ously removed screws.
f. Route each 22-gauge wire to the appropri-
ate turn signal lamp socket. Connect the wire from H2 to
the right turn signal lamp power wire. Connect the wire
from H1 to the left turn signal lamp power wire.
D.
Inspection and Final Installation.
1. Ensure that there are no loose wire strands or
other bare wires which may cause a short circuit. Also, all
wires must be protected from any sharp edges which could
eventually cut through the insulation.
2. Connect the 14-gauge red wire to the (+) posi-
tive terminal of the battery using an in-line, user-supplied
fuseholder and 25A fuse. Locate the fuse as near the bat-
tery as possible to protect the entire length of wire.
NOTE
All directional lamps will illuminate simultaneous-
ly if the power supply leads are reversed. Correct
the wiring before proceeding.
3. Read and understand paragraph IV OPERA-
TION, and test for proper operation of all functions.
c. Connect the terminals on the switch as
shown in figure 2.
3. Illuminated Power Switch.
Improper wiring of the illuminated switch feature
will result in printed circuit board damage. Ensure
that the chassis ground lead is connected to the
gold (pin #3) terminal and that the unterminated
end of the lead is connected to a known good chas-
sis ground.
a. See figure 2. Connect the right angle
terminal on the switch bracket ground lead to the gold (pin
#3) terminal of the on-off switch.
b. Route the unterminated end of the ground
lead to a known good chassis ground. Cut the lead to length
and crimp the supplied ring terminal on the lead.
NOTE
If necessary, additional 18-gauge wire may be
spliced to the ground lead.
c. Secure the lead to the chassis ground with
a user-supplied screw.
4. Turn Signal Connections (optional).
a. Crimp the two right angle terminals on
one end of two user-supplied 22-gauge wires. The wires
-3-
Figure 2.
NOTE: TWO WIRES ARE
CRIMPED IN ONE TERMINAL
NOTE: MATING FEMALE TERMINALS ARE CRIMPED
ON WIRES BEFORE CONNECTING TO SWITCHES.
CONTROL CABLE
ASSEMBLY
BLACK
RED
290A2885B
WHITE
SWITCH BRACKET
REAR VIEW
JUMPER WIRE FROM
INSTALLATION KIT
GREEN
RED
GOLD
TERMINAL
OFF-ON
SWITCH
CHASSIS GROUND
HAZARD
SWITCH
3
2
1
3
2
1
CAUTION
IMPROPER WIRING OF THE ILLUMINATED SWITCH FEATURE
WILL RESULT IN P.C.B. DAMAGE. ENSURE THAT THE CHASSIS GROUND
LEAD IS CONNECTED TO THE GOLD (PIN #3) TERMINAL AND THAT
THE UNTERMINATED END OF THE LEAD IS CONNECTED
TO A KNOWN GOOD CHASSIS GROUND.