Federal Signal Corporation Rumbler 2 Скачать руководство пользователя страница 10

6    

Wiring the Rumbler 2 in the Vehicle

Connecting the Activation Input

Use 22 AWG wire to connect the white activation lead to the vehicle’s horn ring circuit or user sup-

plied momentary switch.

NOTE:

 The 

R

umbleR

 2

 only activates by placing the white activation lead to ground. If activation is 

required from a 12-volt signal, an installer-supplied relay or a Federal Signal UPKM-3 Module must 

be used. The 12-volt signal will energize the relay, and the relay contact will place the white activation 

lead to ground.

Connecting Power

The 

R

umbleR

 2

 operates only from 12-volt NEGATIVE-grounded vehicle electrical system. There-

fore, before making any electrical connections, determine the polarity of the vehicle’s electrical sys-

tem ground.

BATTERY DRAIN

The Rumbler 2 system does not have an on-off switch. If power for the Rumbler 2 is obtained 

directly from the vehicle battery, it draws approximately 0.20 Ah per day in standby mode. If you 

are connecting the Rumbler 2 to the switched side of the ignition circuit, make sure the circuit has 

enough current capacity to handle the additional 10 A (approx.) load.

FUSE AMPLIFIER AT 12 V SOURCE

Damage to the R

umbleR

 2 will occur if it is not properly fused. Ensure that the supplied in-line fuse 

holder and 15 A fuse are installed in the red power lead. The R

umbleR

 2 should also be fused with 

a user supplied 15 A fuse at the 12-volt source.

1.  Use a 14 AWG or heavier wire to connect the amplifier’s black ground lead to the vehicle bat-

tery’s negative terminal (–NEG) or ground lug (Figure 2).

2.  Use a 14 AWG or heavier wire to connect the amplifier’s red lead to the selected 12-volt source. 

290A6109C

CURRENT INPUT LEADS 

(BLACK ZIPCORD)

SPEAKER LEADS 

(CLEAR ZIPCORD)

POSITIVE LEAD (RED WIRE)

FUSE HOLDER

GROUND LEAD (BLACK WIRE)

SIGNAL INPUT LEAD(

(BROWN WIRE)

Содержание Rumbler 2

Страница 1: ...Installation and Operation Instructions 2562420B REV B2 0714 Printed in U S A Model Rumbler 2 Low Frequency Siren Amplifier...

Страница 2: ...blank page...

Страница 3: ...eR 2 in the Vehicle 5 Connecting a Speaker 5 Connecting the Input Leads 5 Connecting the Activation Input 6 Connecting Power 6 Setting the 8 60 Second Timer 7 Testing the RumbleR 2 After Installation...

Страница 4: ...ii Contents...

Страница 5: ...bleR 2 is designed for use in negative grounded vehicles with 12 volt electrical systems It can be mounted in a variety of positions Features Economical small and compact mounts virtually anywhere Eas...

Страница 6: ...other electrical connections are made mounting of all components is complete and you have verified that no shorts exist Be sure the siren amplifier and speaker in your installation have compatible wa...

Страница 7: ...and tags and ensure that the parts listed in Table 2 are contained in the pack ing carton before removing or destroying them Table 2 Parts list Qty Description 1 Amp RumbleR 2 2 Bracket Mounting 2 1 4...

Страница 8: ...k the area into which you plan to drill to ensure you do not damage ve hicle components while drilling All drilled holes should be deburred and all sharp edges should be smoothed All wires going throu...

Страница 9: ...KER The RumbleR 2 siren amplifier is designed to operate only with the Model 751000 RumbleR speaker Connecting the RumbleR 2 to a standard siren speaker will damage the speaker A speaker is not includ...

Страница 10: ...switch If power for the Rumbler 2 is obtained directly from the vehicle battery it draws approximately 0 20 Ah per day in standby mode If you are connecting the Rumbler 2 to the switched side of the i...

Страница 11: ...To protect the operator from sound exposure hearing loss you should measure the sound levels in the vehicle and calculate permissible exposure times One source of permissible exposure times is the fe...

Страница 12: ...e RumbleR 2 5 Check the sound exposure time and make further adjustments if necessary 6 When finished place the cover on the RumbleR 2 and tighten the screws 7 Reinstall the RumbleR 2 in the brackets...

Страница 13: ...s are in front of the speaker If your installation has obstructions in front of the speaker drive even more cautiously Frequently inspect the speaker to ensure that it is clear of any obstruction such...

Страница 14: ...fety instructions and precautions you should follow Read and understand all instructions in this manual before servicing the electronic siren To properly service an electronic siren you must have a go...

Страница 15: ...connect all electrical connections Remove the it from the mounting bracket Send it to the nearest authorized service center or the Federal Signal Service Department After servicing is complete perform...

Страница 16: ...2645 Federal Signal Drive University Park IL 60484 3167 Tel 800 264 3578 Fax 800 682 8022 www fedsig com 2012 Federal Signal Corporation...

Отзывы: