background image

10

Por defecto
Default

GB

E

S-A

(2,3Hz)

ON

A

B

C

D

R-65

 (2Hz)

MLP4/8 FUNCIONAMIENTO

OPERATION MLP4/8

E

GB

2

Quadraflare Advance desactivado (OFF)
Deactivated Quadraflare Advance (OFF)

GB

E

1

Intermitencia OFF
Canal A-C OFF
Canal B-D OFF
Luz Crucero OFF
Cambio Intermitencia OFF
Día/Noche OFF

OFF Flash Pattern
OFF A-C Channel
OFF B-D Channel
OFF Cruise Light
OFF Flash Patern Change
OFF Day/Night

GB

E

A

B

C

D

4

Luz activada modo Luz Crucero
Cruise Light mode activated light

GB

E

3

Intermitencia OFF
Canal A-C OFF
Canal B-D OFF

Luz Crucero 

ON

Cambio Intermitencia OFF
Día/Noche OFF

OFF Flash Pattern
OFF A-C Channel
OFF B-D Channel

ON

 Cruise Light

OFF Flash Patern Change
OFF Day/Night

GB

E

5

Intermitencia OFF
Canal A-C OFF
Canal B-D OFF

Luz Crucero 

ON

Cambio Intermitencia OFF
Día/Noche OFF

OFF Flash Pattern
OFF A-C Channel
OFF B-D Channel

ON

 Cruise Light

OFF Flash Patern Change
OFF Day/Night

GB

E

6

Intermitencia 

ON

Canal A-C OFF
Canal B-D OFF
Luz Crucero ON
Cambio Intermitencia OFF
Día/Noche OFF

ON

 Flash Pattern

OFF A-C Channel
OFF B-D Channel
ON Cruise Light
OFF Flash Patern Change
OFF Day/Night

GB

E

2

Luz activada modo Noche
Night mode activated light

1

Intermitencia ON
Canal A-C OFF
Canal B-D OFF
Luz Crucero OFF
Cambio Intermitencia OFF

Día/Noche 

ON

ON Flash Pattern
OFF A-C Channel
OFF B-D Channel
OFF Cruise Light
OFF Flash Patern Change

ON

 Day/Night

GB

E

ON

A

B

C

D

ON

A

B

C

D

S-A

 (2,3Hz)

Содержание QuadraFlare Advance CL2

Страница 1: ...draFlare QuadraFlare QuadraFlare Advance CL2 Advance CL2 Advance CL2 Advance CL2 Advance CL2 refs 2010617 18 23 24 C ARCHIVO DOCUMENT FOCOS REF DOC 91471788 F U R 27 09 13 REVISI N 1 FEDERAL SIGNAL VA...

Страница 2: ...nts E GB GB E Quadraflare Advance CL2 modo d a noche sin intermitencia Quadraflare Advance CL2 day night mode without flash Modelos Models E GB R65 CL2 ref azul blue mbar amber rojo red blanco white v...

Страница 3: ...funcionamiento 20 50 C Temperatura de funciona 20 50 C Use temperature Use temperature Consumo medio modo fijo 1 A 12V 0 7 A 24V Consumo medio 0 02 A 10 30V Steady burn mode average consumption Avera...

Страница 4: ...ADVERTENCIA Para cumplir con la Norma Europea R 65 El foco QuadraFlare Advance lente lisa led azul lente azul o cristal ha de instalarse horizontalmente ver fig 4 Los focos QuadraFlare Advance han de...

Страница 5: ...Necessary material not supplied 18 mm 3 mm Philips PH3 FUSE 7 A FUSE 3 x 0 5 A Nitrato de zinc Zinc nitrate GB E 1 2 3 4 Nitrato de zinc Zinc nitrate Nitrate de zinc Zinknitrat Nitrato di zinco I D F...

Страница 6: ...tallation instructions Necessary material not supplied 18 mm 3 mm Philips PH3 FUSE 7 A FUSE 3 x 0 5 A Nitrato de zinc Zinc nitrate GB E 1 2 3 4 Nitrato de zinc Zinc nitrate Nitrate de zinc Zinknitrat...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...cia ON Canal A C OFF Canal B D OFF Luz Crucero OFF Cambio Intermitencia OFF D a Noche OFF ON Flash Pattern OFF A C Channel OFF B D Channel OFF Cruise Light OFF Flash Patern Change OFF Day Night GB E 5...

Страница 11: ...C Channel OFF B D Channel ON Cruise Light OFF Flash Patern Change OFF Day Night GB E 5 Intermitencia OFF Canal A C OFF Canal B D OFF Luz Crucero ON Cambio Intermitencia OFF D a Noche OFF OFF Flash Pat...

Страница 12: ...150 2 5Hz Intermitencia ON Cambio Intermitencia ON ON Flash Pattern ON Flash Patern Change GB E Intermitencia ON Cambio Intermitencia ON ON Flash Pattern ON Flash Patern Change GB E Intermitencia ON C...

Страница 13: ...er 1x ref 2006030 12x ref 9018368 1x ref 9018354 1x ref 9018355 1x ref 8012016 4x ref 9027245 1x ref 9018576 1x ref 9018508 RECAMBIOS SPARE PARTS E GB MLP F4 flasher 1x ref 2006035 2x ref 9018354 9x r...

Страница 14: ...e estas instrucciones en un lugar seguro y rem tase a ellas cuando efect e operaciones de mantenimiento o reinstale el producto El no cumplimiento de estas normas de precauci n puede dar como resultad...