![Federal Signal Corporation P-LS2B Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/federal-signal-corporation/p-ls2b/p-ls2b_installation-operation-and-maintenance-instructions_548504017.webp)
17
PAGASYS Series Loudspeaker
Periodically Inspecting the Loudspeaker
Establishing a regular inspection schedule for the loudspeaker extends
the life of the loudspeaker and ensures safety. For a list of replacement
parts see page 19.
•
Ensure that the the loudspeaker is maintained in line with the
regulations in force and at regular intervals, at least once per year.
•
Check for external damage and repair and replace as necessary.
•
Check that the gasket is seated properly and that it is not brittle or
damaged.
•
Periodic checks should be made to ensure that the effectiveness
of this device has not been reduced because the speaker has
become clogged with a foreign substance or because objects have
been placed in front of the speaker.
•
Check all earth connections.
•
Check for water/dust ingress and replace seals as necessary.
Servicing the Loudspeaker
SHOCK HAZARD
To avoid an electrical shock, do not connect the loudspeaker to
the system while the power is on.
FOR MODELS P-LS2B AND P-LS2C ONLY:
The loudspeaker is fully encapsulated and the speaker driver is non-
serviceable. If the driver fails, the entire loudspeaker must be replaced.
If it does not operate, verify continuity of the fuse module before
replacing the loudspeaker (Figure 3 on page 14). The fuse module,
which contains a thermal fuse and a current fuse, is a replaceable part.
For ordering information, see page 19.
To replace the fuse:
1. Turn off power to the loudspeaker.
2. Remove the four screws securing the rear cover to the
loudspeaker, and remove the cover.
3. Disconnect the leads of the fuse module from the terminal block.