Federal Signal Corporation MICROSTAT MSL Скачать руководство пользователя страница 4

4

  

  

the bottom lens. Each module has an O-ring on it to keep it  

watertight. Retain all O-rings.

b. Remove the two phillips head #6 screws and disassemble the sleeve(s) from the 

base. The printed circuit board will remain attached to the sleeve(s).

c. Thread the MSL base onto the pipe.

After the MSL base is installed, refer to section D for information on installing the 

Light Module and making the electrical connections.

2. Surface Mounting.

There are two options available for surface mounting. The first option is to mount 

Model MSL directly on the surface of machines, cabinets, control boards, or any 

installations where a rigid flat surface is available. This installation is described 

below. If raised mounting is desired for greater visibility, use the tulip mount 

base (MSTB) and one of three lengths of extension pipes (MSP). The installation 

instructions for the second option is described in the instruction sheet for Model 

MSB. The MicroStat

 comes assembled from the factory. It is necessary to remove 

the base from the unit to surface mount. To surface mount the base,  

perform the following steps (refer to Figure 2):

a. Remove the entire stack of colored lenses by twisting the very bottom lens 

counter-clockwise (as viewed from the top) until it unlocks. Lift the bottom lens 

upward and off the base unit. The other colored lenses should remain attached to 

the bottom lens. Each module has an O-ring on it to keep it  

watertight. Retain all O-rings.

b. Remove the two phillips head #6 screws and disassemble the sleeve(s) from the 

base. The printed circuit board will remain attached to the sleeve(s).

c. Use the gasket or the template included in this instruction sheet as a guide, plac-

ing either onto a flat section of the surface at the device’s  

intended location.

d. Mark the four mounting holes and the center clearance hole.
e. Drill the four mounting holes using a #34 drill. In the center of the 4 hole pattern, 

drill the large clearance hole using a 1” hole saw.

f.  Knock out the four surface mount holes at the bottom of the MSL base.
g. Locate the gasket on the surface and place the base on top of the gasket. Secure 

the base with the appropriate #6 screws.

CAUTION

Excessive torque on the mounting screws may crack the base.  

Do not over tighten the screws.

After the base is installed, refer to section D for information on installing the Light 

Module and making the electrical connections.

C. Specifications.

Operating Voltage 

24 Vdc/ac 

120 Vac 50-60 Hz 

Lamp 

28 V, 5.6 W 

28 V, 5.6 W 

Lamp Type 

655 Standard glass wedge based

Lamp Life (Based on AC operating voltage)  7000 Hours Average

Содержание MICROSTAT MSL

Страница 1: ...STAT STATUS INDICATOR MODEL MSL MODELO MSL HOJA DE INSTRUCCIONES INDICADOR DE ESTADO MODELO MSL DE FEDERAL SIGNAL MICROSTAT MOD LE MSL FICHE D INSTRUCTIONS CONCERNANT L INDICATEUR D TAT MICROSTAT DE F...

Страница 2: ...or warning sirens and controllers manufactured by Federal Warning Systems are warranteed for two years on parts and one year on labor No agent employee representative or distributor of Seller has any...

Страница 3: ...aded joints are properly tightened After installation test the light system to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all operating...

Страница 4: ...lens counter clockwise as viewed from the top until it unlocks Lift the bottom lens upward and off the base unit The other colored lenses should remain attached to the bottom lens Each module has an O...

Страница 5: ...may be removed individually or as a group To remove an individual lens starting with the top ap ply a counter clockwise as viewed from the top twisting motion until it unlocks Lift the lens upward an...

Страница 6: ...ns until it locks into place The colored lenses can be assembled to the unit in the sequence determined by the user 8 Test the MicroStat to ensure that it operates as intended II RELAMPING WARNING To...

Страница 7: ...stributor or manufacturer s representative At this time a brief explanation of the service requested or the nature of the malfunction should be provided Address all communications and shipments to Ind...

Страница 8: ...s y los controladores fabricados por Federal Warning Systems est n garantizados por dos a os sobre las piezas y un a o sobre la mano de obra Ning n agente empleado representante o distribuidor del Ven...

Страница 9: ...s antes de instalar o poner este equipo en funcionamiento No conectar esta luz al sistema cuando est en marcha Despu s de la instalaci n comprobar que todos los tornillos y juntas roscadas est n corre...

Страница 10: ...alaci n para la segunda opci n se describen en la hoja de instrucciones para el Modelo MSB El MicroStat est montado en la f brica Es necesario quitar la base de la unidad para montarlo sobre una super...

Страница 11: ...l color de la lente para cada m dulo de luz y la secuencia de los m dulos de luz est determinada por el usuario Si el Modelo MSL no se ha desmontado previamente para su montaje efectuar los siguientes...

Страница 12: ...r evidente Con cada MicroStat se incluyen pantallas para la luz a modo opcional para solucionar este problema Para instalarlas poner la pantalla sobre la l mpara y presionarla como se indica en la Fig...

Страница 13: ...que tenga un problema que no se puede solucionar localmente Toda unidad que sea enviada a Federal Signal para su reparaci n inspecci n o mantenimiento debe ir acompa ada de una Autorizaci n de Devoluc...

Страница 14: ...ext rieures et les contr leurs fabriqu s par Federal Warning Systems sont couverts par une garantie de deux ans sur les pi ces et de un an sur la main d uvre Aucun agent employ repr sentant ou distrib...

Страница 15: ...ant d installer ou d utiliser ce mat riel Ne connectez pas cette lampe au syst me si la tension est pr sente Apr s installation assurez vous que toutes les vis et les joints filet s sont bien serr s A...

Страница 16: ...ructions d installation pour la seconde option sont d crites dans la fiche d instructions du Mod le MSB Le MicroStat est assembl en usine Il est n cessaire de retirer la base de l appareil pour faire...

Страница 17: ...iff rentes bas es sur le nombre de modules de lampes Voir figure 3 Les Mod les MSL3 MSL4 et MSL5 se font chacun avec cinq verres de couleurs diff rentes La couleur du verre de chaque module de lampe e...

Страница 18: ...d oeil et un passage de lumi re entre les modules peut tre vident Des cache lumi re sont inclus en option avec chaque MicroStat pour r soudre ce probl me Pour installer placez l cran sur la lampe et e...

Страница 19: ...me ne pouvant tre trait localement Les unit s renvoy es Federal Signal pour entretien inspection ou r paration doivent tre accompagn es d une Autorisation de Retour de Mat riel Cette ARM R M A peut t...

Страница 20: ...rew F Colored lens up to five G Cap Espa ol A Base B Junta t rica C Placa de circuito impreso D Manga E Tornillo Phillips de cabeza 6 F Lentes de color hasta 5 G Tapa Fran ais A Base B Joint torique C...

Страница 21: ...Gasket J Mounting surface Espa ol A Base B Junta t rica C Placa de circuito impreso D Manga E Tornillo Phillips de cabeza 6 F Lentes de Color hasta 5 G Tapa H Cu a J Superficie de montaje Fran ais A B...

Страница 22: ...22 3 290A3379 9 765 248 031mm 12 515 317 881mm 16 515 419 481mm 17 515 444 881mm 7 765 197 231mm 2 200 55 880mm...

Страница 23: ...de bornas hembra para las conexiones de los cables B Conector macho C Destellador electr nico opcional En este ejemplo las l mparas 4 y 5 est n destellando y las l mparas 1 2 y 3 iluminan de forma fij...

Страница 24: ...al B Portal mpara y montaje de la tapa C L mpara tipo cu a 655 Fran ais A cran option B Douille de lampe et couvercle C Lampe a tige de verre 655 5 Industrial Systems 2645 Federal Signal Drive Univers...

Отзывы: