Specifications

Informer15 Speaker (Model I-IP15 Series C) 

Federal Signal www.fedsig.com

Ordering Information

Table 1 Ordering Information

Part Number Description

I-IP15-W

15 W PoE Speaker with white high-output LED

I-IP15-R

15 W PoE Speaker with red high-output LED

I-IP15-A

15 W PoE Speaker with amber high-output LED

I-IP15-B

15 W PoE Speaker with blue high-output LED

I-IP15-G

15 W PoE Speaker with green high-output LED

I-IP15-024-W 15 W, 24 Vdc, Speaker with white high-output LED
I-IP15-024-R 15 W, 24 Vdc, Speaker with red high-output LED
I-IP15-024-A 15 W, 24 Vdc, Speaker with amber high-output LED
I-IP15-024-B 15 W, 24 Vdc, Speaker with blue high-output LED
I-IP15-024-G 15 W, 24 Vdc, Speaker with green high-output LED

Specifications

Table 2 Electrical Requirements

Input Power for PoE model

Power over Ethernet (PoE+ 802.3at) 48 Vdc

Requires 25.5 W

Input Power for 24 Vdc model

24 Vdc, 1.0 A

Serial Port Protocol

FLASH programming and configuration 

Default: 9600 bit/s, 8 data, 1 stop, no parity.  

Configurable up to 115,200 bit/s

Open Collector Output

Maximum 30 V or 100 mA maximum,  

(speaker pr24 Vdc, 20 mA maximum for external 

relay)

Ethernet Port for PoE model

IEEE 802.3, 10/100 Base-T connection with PoE+ 

802.3at, Type 2, 25.5 W

Ethernet Port for 24 Vdc model IEEE 802.3, 10/100 Base-T connection
Alarm Initiating Inputs

Four optically Isolated Inputs

Audio Storage

Warning siren audio, seven factory-installed tones: Wail, 

Steady, Alternate Wail, Alternate Steady, Pulsed Wail, 

Pulsed Steady, Auxiliary Chime 

Prerecorded files

up to 4000 messages with up to  

17 hours of recording time

Audio Data

8 bit 8 kHz mono WAV

Audio Frequency response

300 Hz to 3000 Hz, +1 to -3 dB per octave

Maximum Audio Output

15 W, 112 dB for tones and 107 dB for pink noise at 

10 feet

Power Output

15 W into 8 ohm load 

Frequency response

+/- 3 dB from 300-6.0 kHz

THD

< 5% at output

Hum and Noise

< -45 dB

Input Levels

1.77 V

RMS

 (5 V

P-P

), 10 V

RMS

(28.3 V

P-P

) and 25 V

RMS

  

(70.7 V

P-P

)

Содержание Informer15 I-IP15

Страница 1: ...ecifications Installation Operation and Service Manual 25500494 Rev C1 1220 Printed in U S A Copyright 2018 2020 Federal Signal Corporation Informer15 Speaker Model I IP15 Series C IP Enabled Indoor O...

Страница 2: ...all 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness...

Страница 3: ...cifications 10 Installation 13 Flat Surface Mounting 14 Opening the Housing 15 Wiring the Network and Power Connections 15 PoE model See Figure 2 15 24 Vdc model See Figure 3 16 Wiring to the Controll...

Страница 4: ...s for the Controller Board 11 Table 4 Connectors and Jacks for the Amplifier Board 11 Table 5 Connectors and Jacks for the PoE Board PoE models only 12 Table 6 Connectors for the 24 Vdc Power Board 12...

Страница 5: ...ens Review and comply with any local or state noise control ordinances as well as OSHA noise exposure regulations and guidelines Activating the Informer15 Speaker may not result in people taking the d...

Страница 6: ...obstruct the sound output reducing the effectiveness of the horn Establish a procedure to check the signal system for proper activation and operation routinely Any maintenance to the unit MUST be perf...

Страница 7: ...e power wiring or lightning rods and associated wires and at least six inches from other wire for example antenna wires doorbell wires wires from transformers to neon signs steam or hot water pipes an...

Страница 8: ...cation has no network connectivity but where voice and tone alerts from locally activated inputs are required The Informer15 can be networked later and the activations can be brought into the Commande...

Страница 9: ...or volume and noise level adjustments Speaker as a microphone for talkback feature Alerts can be sent to single devices groups or zones or all devices Integrated Modbus TCP industrial PLC interface fo...

Страница 10: ...4 Vdc model 24 Vdc 1 0 A Serial Port Protocol FLASH programming and configuration Default 9600 bit s 8 data 1 stop no parity Configurable up to 115 200 bit s Open Collector Output Maximum 30 V or 100...

Страница 11: ...lector Output 2 Output 1 24 Vdc JP8 Option1 Jumper Short pins 1 and 2 for Standalone Option JP9 Option2 Jumper Short pins 1 and 2 for Option JP11 Serial Port RJ25 6 conductor mod jack JP12 Controller...

Страница 12: ...al Indications for the Controller Board D1 Power D2 Digital Input 1 active D3 Listen D4 Talk D5 Digital Input 2 active D7 Network connected D8 CPU running D9 Digital Input 3 active D11 Digital Input 4...

Страница 13: ...allation crew safety foreman should perform the installation OBSTRUCTION HAZARD Property damage serious injury or death could occur if an accumulation of water snow dust etc resides in the speaker pro...

Страница 14: ...ing surface See Figure 1 for mounting hole locations and dimensions DRILLING PRECAUTION Before drilling holes in any surface ensure that both sides of surface are clear of items that could be damaged...

Страница 15: ...an eight pin Ethernet port for connecting to the network Ethernet wire runs must be less than 328 feet 100 meters from the nearest network switch Do not install in a conduit carrying high voltage The...

Страница 16: ...ler Board 24 Vdc Power Input Board Amplifier Board To Amplifier Board To 24 Vdc Power Input Board JP1 JP2 JP3 M1 GND GND 24 Vdc 24 Vdc Wiring to the Controller Board To wire the Controller Board 1 Use...

Страница 17: ...ations section of this manual When using this feature the open collector relay outputs turn on until one of the following occurs Until the programmed default timeout occurs Until the CANCEL or RESET c...

Страница 18: ...ial system test establish a program for periodic testing of this device 3 Provide a copy of these instructions for the Safety Engineer system operator s and maintenance personnel Safety Message to Ope...

Страница 19: ...als If a volume adjustment or other repair is required be sure to refer to the Safety Message before proceeding SOUND HAZARD Unauthorized repair servicing of the unit may result in degradation of perf...

Страница 20: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400...

Отзывы: