General Description

Informer15 Speaker (Model I-IP15 Series C) 

Federal Signal www.fedsig.com

General Description

Overview

The Informer15 Speaker is a 15-watt, IP-enabled indoor and outdoor speaker. Use the 

Informer15 as a warning and alert device with both audible and visual indicators. The 

audible capabilities include locally stored, high-quality, high-powered tones and voice 

messages. The visual indicators include an integrated high-powered LED light and 

an optional scrolling message display that can be controlled by the Informer15. The 

Informer15 can be equipped with up to four local initiation devices (switches) to activate 

the unit locally and to the Commander® controller for mass notification communications.  
The Informer15 Speaker has an internal 15-watt amplifier/driver to deliver tone warnings 

and intelligible voice messages from Informer15 stored memory. The Informer15 also has 

several unique capabilities when working with the Federal Signal Commander software. 

Using Commander software, the Informer15 can play text-to-speech, stream WAV files, or 

broadcast live PA. Commander software can perform a talk/listen to individual Informer15s 

to allow call-box type communications. The Informer15 also has remote volume control for 

optimizing sound levels across your alerting area. Remote volume control also includes 

an ambient-noise-monitoring capability to automatically adjust the volume depending on 

external noise levels. 

The Informer15 can be programmed and configured as a standalone device to only use 

the inputs to activate the Informer15. This may be useful if the location has no network 

connectivity but where voice and tone alerts from locally activated inputs are required. 

The Informer15 can be networked later, and the activations can be brought into the 

Commander system for full system capability. When the Informer15 is networked using 

the Commander software, alerts initiated at the Informer15 can be used to activate other 

devices. The Commander software system can also alert emergency personnel via email, 

SMS, and handheld radios using optional messaging software.

The Informer15 includes one output to control the visual indicator and an output to 

activate an external relay, which can be used to control external devices. The Informer15 

has two 1/2-inch NPT openings on the bottom of the speaker for simple installation of 

pipe-mount devices. The openings allow access to LAN, open collector output, and 

activation inputs. The Commander system allows multiple configurations for activation of 

the open collector output or visual indicator during alerts.
The Informer15 is designed for outdoor use and large indoor structures. A 24 Vdc and 

a POE+ model are available. The POE+ version of the Informer15 obtains its operating 

voltage solely from a POE+ (IEEE 802.3at) network switch or power injector. No other 

AC or DC power is required for the integrated speaker or light. All wiring interfaces 

are accessible via internal connectors and built-in NPT entrances for quick and easy 

installation.
The Informer15 Speaker is a perfect addition to existing notification systems where lack of 

coverage exists. The unit can be used as a call station where emergency alert buttons are 

required.

See the Informer-IP Series C Setup, Program, and User Manual (part number 25500395 

revision C or later) to learn how to set up, configure, program, and use Informer-IP 

devices.

Содержание I-IP15

Страница 1: ...pecifications Installation Operation and Service Manual 25500494 Rev C1 1220 Printed in U S A Copyright 2018 2020 Federal Signal Corporation Informer15 Speaker Model I IP15 Series C IP Enabled Indoor Outdoor Speaker ...

Страница 2: ...call 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular purpose and any warranty against failure of its essential purpose 2645 Federal Signal Drive University Park Illinois 60484 www fedsig com Customer Support 800 548 7229 1 708 534 340...

Страница 3: ...ecifications 10 Installation 13 Flat Surface Mounting 14 Opening the Housing 15 Wiring the Network and Power Connections 15 PoE model See Figure 2 15 24 Vdc model See Figure 3 16 Wiring to the Controller Board 16 Closing the Housing 18 Testing 18 Maintenance 18 Ordering Replacement Parts 19 Getting Service 19 Figures Figure 1 Depth and Height of Informer15 Speaker 14 Figure 2 I IP15 PC Boards 15 F...

Страница 4: ...ks for the Controller Board 11 Table 4 Connectors and Jacks for the Amplifier Board 11 Table 5 Connectors and Jacks for the PoE Board PoE models only 12 Table 6 Connectors for the 24 Vdc Power Board 12 Table 7 Visual Indications for the Controller Board 12 Table 8 Visual Indications for Amplifier Board 12 Table 9 Environmental and Physical 12 Table 10 Replacement Parts 19 ...

Страница 5: ...rens Review and comply with any local or state noise control ordinances as well as OSHA noise exposure regulations and guidelines Activating the Informer15 Speaker may not result in people taking the desired actions if those to be warned are not properly trained about the meaning of warning sounds Users should follow FEMA recommendations and instruct those to be warned of corrective actions to be ...

Страница 6: ... obstruct the sound output reducing the effectiveness of the horn Establish a procedure to check the signal system for proper activation and operation routinely Any maintenance to the unit MUST be performed by a trained electrician per NEC Guidelines and local codes or a Federal Signal certified Service Provider Never alter the unit in any manner The nameplate should NOT be obscured as it contains...

Страница 7: ...re power wiring or lightning rods and associated wires and at least six inches from other wire for example antenna wires doorbell wires wires from transformers to neon signs steam or hot water pipes and heating ducts Do not place Ethernet wiring or connections in any conduit outlet or junction box containing high voltage electrical wiring If using a cable gland the gland must be UL listed The Info...

Страница 8: ...ocation has no network connectivity but where voice and tone alerts from locally activated inputs are required The Informer15 can be networked later and the activations can be brought into the Commander system for full system capability When the Informer15 is networked using the Commander software alerts initiated at the Informer15 can be used to activate other devices The Commander software syste...

Страница 9: ...for volume and noise level adjustments Speaker as a microphone for talkback feature Alerts can be sent to single devices groups or zones or all devices Integrated Modbus TCP industrial PLC interface for control and monitoring Integrated SIP phone interface for live PA remote WAV file and function control Commander and CommanderOne HMI software provide configuration control activation and notificat...

Страница 10: ...24 Vdc model 24 Vdc 1 0 A Serial Port Protocol FLASH programming and configuration Default 9600 bit s 8 data 1 stop no parity Configurable up to 115 200 bit s Open Collector Output Maximum 30 V or 100 mA maximum speaker provides 24 Vdc 20 mA maximum for external relay Ethernet Port for PoE model IEEE 802 3 10 100 Base T connection with PoE 802 3at Type 2 25 5 W Ethernet Port for 24 Vdc model IEEE ...

Страница 11: ...llector Output 2 Output 1 24 Vdc JP8 Option1 Jumper Short pins 1 and 2 for Standalone Option JP9 Option2 Jumper Short pins 1 and 2 for Option JP11 Serial Port RJ25 6 conductor mod jack JP12 Controller to Amplifier Interface JP13 microSD FLASH card holder M1 Communications from PoE board Table 4 Connectors and Jacks for the Amplifier Board JP1 Power Input from PoE board or the 24 Vdc power board JP...

Страница 12: ...ual Indications for the Controller Board D1 Power D2 Digital Input 1 active D3 Listen D4 Talk D5 Digital Input 2 active D7 Network connected D8 CPU running D9 Digital Input 3 active D11 Digital Input 4 active D19 Relay Output active Table 8 Visual Indications for Amplifier Board D6 Power LED D8 ARM LED Table 9 Environmental and Physical Operating temperature range 22 F to 149 F 30 C to 65 C Humidi...

Страница 13: ...tallation crew safety foreman should perform the installation OBSTRUCTION HAZARD Property damage serious injury or death could occur if an accumulation of water snow dust etc resides in the speaker projector or if any objects are in front of the speaker severely reducing or preventing operation of this device Mount the unit so speaker projector is pointed horizontally or slightly downward and ensu...

Страница 14: ...ing surface See Figure 1 for mounting hole locations and dimensions DRILLING PRECAUTION Before drilling holes in any surface ensure that both sides of surface are clear of items that could be damaged 3 Secure the unit to a wooden mounting surface with 10 x 1 inch wood screws If mounting on a metal surface drill 13 64 inch diameter holes and secure the unit with 10 screws lock washers and nuts 4 Ro...

Страница 15: ...s an eight pin Ethernet port for connecting to the network Ethernet wire runs must be less than 328 feet 100 meters from the nearest network switch Do not install in a conduit carrying high voltage The wired Ethernet port auto negotiates a 10 100 full or half duplex connection and provides PoE to the Informer15 Speaker Do not remove the prewired Ethernet cable between the PoE supply PCB J2 and the...

Страница 16: ...ller Board 24 Vdc Power Input Board Amplifier Board To Amplifier Board To 24 Vdc Power Input Board JP1 JP2 JP3 M1 GND GND 24 Vdc 24 Vdc Wiring to the Controller Board To wire the Controller Board 1 Use JP13 to provide tone and messages into the Informer15 via the microSD memory card 2 If local activations are required use JP2 The Alarm Initiation Inputs are activated by shorting the input to the I...

Страница 17: ...cations section of this manual When using this feature the open collector relay outputs turn on until one of the following occurs Until the programmed default timeout occurs Until the CANCEL or RESET command is received You can configure the open collector relay output to open close and cycle based on a pre programmed sequence The open collector relay output can also be configured to turn on when ...

Страница 18: ...tial system test establish a program for periodic testing of this device 3 Provide a copy of these instructions for the Safety Engineer system operator s and maintenance personnel Safety Message to Operators Even if your warning system is operating properly it may not be completely effective People may not hear or heed your warning signal You must recognize this fact and ensure that your warning s...

Страница 19: ...vals If a volume adjustment or other repair is required be sure to refer to the Safety Message before proceeding SOUND HAZARD Unauthorized repair servicing of the unit may result in degradation of performance and or safety resulting in property damage serious injury or death to you or others If a malfunctioning unit is encountered do not attempt any field repair retrofit of parts Ordering Replacem...

Страница 20: ...2645 Federal Signal Drive University Park Illinois 60484 3167 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 3400 ...

Отзывы: