7
Federal Signal
signaling.fedsig.com
5.
If using an alternate power supply, connect the supply to the terminal block J9. Before doing so, determine if
power is supplied over the Ethernet cable.
6.
Connect the on-board relay if utilized.
7.
Reconnect the faceplate harness.
8.
Ensure that all connections are secure.
9.
Verify that the telephone is properly connected by pressing the RESET switch for less than five seconds to
announce the IP address. LEDs on the RJ45 connector indicate network connection and activity.
10.
Replace the faceplate.
11.
Set up and configure the telephone if changes are required to the default settings.
12.
Call to and from another telephone, preferably a VoIP device, to test the unit.
Operation
The FT200C-V telephone may be set up for either keypad dialing or auto-dialing.
If the telephone is configured for keypad, dialing operation is identical to most other single-line telephones.
If the telephone is configured for auto dialing, lift the handset and press the number assigned to the extension to be
dialed.
The telephone dials the programmed number when the handset is lifted.
Adjust the receiver volume with the switch in the handset.
Setup
Connections
Figure 6 shows the pin connections on the J9 (terminal block). This terminal block can accept a wire range from 16 AWG
to 26 AWG.
NOTE:
As an alternative to using PoE power, 24 V at 1 A can be supplied to the terminal block.
Figure 6 Terminal Block Connections