background image

-3-

A. Re-lamping.

To change the lamp, proceed as follows:

1.  Disconnect power
2.  Remove the screw located at the bottom of the dome.
3.  Grasp the top of the dome and push down while turning the dome counter-clockwise ap-

proximately 3/4-inch (19 mm).

4.  Gently lift dome away. Ensure that the gasket between the dome and base is not lost.
5.  Replace lamp with the appropriate federal signal lamp. (see section E)
6.  Before replacing dome, ensure that the gasket is properly seated. Place the dome over the 

base, aligning the recesses inside the dome lip with the four pins on the base. Push down on 
the dome and turn clockwise until it locks in place (approximately 3/4-inch, 19mm).

7.  Replace the screw into the bottom of the dome.

B. Cleaning Reflector.

Remove and replace dome in accordance with instructions in paragraph III.A. To clean reflec-
tor, use a soft cloth and any liquid household cleaner. DO NOT UsE abrasive cleaners.

C. Cleaning Enclosure.

NOTE

Maintenance procedures sometimes require fixtures to be hosed down for good housekeeping. 

The fixture should be cleaned periodically to maintain maximum light output. Only mild, non-
abrasive cleaning agents should be used. The dome should be regularly inspected for scratches 
and chips, and, if damaged, must be replaced.

In extremely corrosive locations, equipment should be periodically inspected to guard against un-

usual deterioration and possible porosity, since this may weaken the enclosure structurally.

D. Lubrication.

The Motor-Gear Reducer Assembly is a sealed unit. Therefore, no lubrication is required.

E. Replacement Parts.

Description 

Part Number

Dome Assembly, Amber 

K8444D219-03

Dome Assembly, Blue 

K8444D219-01

Dome Assembly, Clear 

K8444D219-04

Dome Assembly, Green 

K8444D219-02

Dome Assembly, Red 

K8444D219

Lamp, 25T8DC, 130 V 

K149123A

Lamp, 25T8DC, 240 V 

K8107A149A

Gasket 

K8444286B

F.  Service.

The federal signal factory will service your equipment or provide technical assistance with any 
problems that cannot be handled locally.
Any units returned to federal signal for service, inspection, or repair must be accompanied 
by a Return Material Authorization. This R.M.A. can be obtained from the local Distributor or 
Manufacturer’s Representative.
At this time a brief explanation of the service requested, or the nature of the malfunction, 
should be provided.

Содержание ELECTRARAY 225X

Страница 1: ...MODELO 225X INSTRUCCIONES DE INSTALACIÓN Y ASISTENCIA TÉCNICA DEL MODELO 225X DE ALUMBRADO ELECTRARAY DISEÑADO PARA ENTORNOS O UBICACIONES DE RIESGO MODÈLE 225X INSTRUCTIONS D INSTALLATION ET D ENTRETIEN POUR LA LAMPE ELECTRARAY MODÈLE 225X POUR UTILISATION DANS DES ENDROITS DIFFICILES DANGEREUX 2561257F REV F 209 Printed in U S A ...

Страница 2: ...ation test the light system to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all operating personnel Establish a procedure to routinely check the light installation for integrity and proper operation Failure to follow all safety precautions and instructions may result in property damage serious injury or death to you or others I GENERAL ...

Страница 3: ...INTENANCE To prevent ignition of hazardous atmospheres disconnect the fixture from the supply circuit before opening Keep tightly closed when in operation SAFETY MESSAGE TO MAINTENANCE PERSONNEL Listed below are some important safety instructions and precautions you should follow Read and understand all instructions before operating this system Any maintenance to the light system must be done with...

Страница 4: ...e cleaned periodically to maintain maximum light output Only mild non abrasive cleaning agents should be used The dome should be regularly inspected for scratches and chips and if damaged must be replaced In extremely corrosive locations equipment should be periodically inspected to guard against un usual deterioration and possible porosity since this may weaken the enclosure structurally D Lubric...

Страница 5: ...equacy relative to alerting hearing impaired individuals in a fire alarm system To prevent misapplication of a visual signal appliance Listed to UL1638 UL determined it is the manufacturer s responsibility to warn the installer in the field and Authority Having Jurisdic tion AHJ of what would be an inappropriate use of the product Therefore manufactures whose products Listed to UL1638 are required...

Страница 6: ... demás tuercas estén completamente engranadas Tras haber procedido a su instalación revise el sistema de alumbrado para asegurarse de que funciona correctamente Después de haberlo revisado facilite una copia de esta hoja de instrucciones a todo el personal operativo Establezca un método rutinario de chequeo de la instalación del alumbrado para comprobar que su funcionamiento es totalmente correcto...

Страница 7: ...or negro al lado común de la fase de la fuente de energía el conector blanco al lado común neutral de la fuente de energía y el conector verde amarillo a la tierra Si se requiere el conector verde amarillo que se encuentra en la cubierta se proporciona para realizar la conexión de descarga a tierra NOTA Las unidades están diseñadas para funcionar tanto a 50 como a 60 Hz De potencia eléctrica NO ES...

Страница 8: ...iste entre la pantalla y la base no se extravíe 4 Sustituya la lámpara por otra de Federal Signal Pieza Nº 149123 25T8CC 130V 5 Antes de reemplazar el domo asegúrese de que la junta esté adecuadamente asentada Co loque el domo sobre la base alineando los recesos dentro del borde del domo con las cuatro clavijas en la base Empuje el domo hacia abajo y gire en sentido horario hasta que se trabe en s...

Страница 9: ...arma visual en modo pú blico QUÉ SIGNIFICA ESTO Underwriters Laboratories usa dos normas diferentes para investigar y listar aparatos de señalización visual La primera norma UL para seguridad es la UL1971 Dispositivos de señalización para perso nas con discapacidad auditiva Esta norma cubre dispositivos de señalización visual diseñados para sistemas de alarma de incendio para alertar a personas co...

Страница 10: ... Aparato de notificación Componente de un sistema de alarma de incendio como una campana una bocina un altavoz una luz o una pantalla de texto que proporciona una salida auditiva táctil o visible o cualquier combinación de los mismos En otras palabras este dispositivo no debería usarse como componente de un sistema comercial de alarma de incendio ...

Страница 11: ...jonctions filetées sont entièrement engagées Après installation essayez le système de lampe pour assurer qu il fonctionne correctement Après la fin de l essai fournissez un exemplaire de cette fiche d instructions à tout le personnel d utilisation Établissez une procédure pour vous assurer systématiquement que le système de lampe peut être mis sous tension et fonctionner correctement Le non respec...

Страница 12: ...gie et mettez le fil vert jaune à la terre Au besoin le fil vert jaune dans l enveloppe est fourni pour la mise à la terre NOTA Les appareils sont conéus pour fonctionner en 50 et 60 Hz AUCUNE modification n est nécessaire pour les deux fréquences différentes III ENTRETIEN Pour éviter l inflammation d atmosphères dangereuses débranchez le dispositif du circuit d alimentation avant d ouvrir Gardez ...

Страница 13: ... les quatre bornes sur la base Poussez vers le bas sur le dôme et tournez dans le sens des aiguilles d une montre jusqu à ce que le tout se verrouille en place environ 3 4 pouce 1 9 cm 6 Remettez la vis dans le bas du dôme B Nettoyage du Réflecteur Retirez et remplacez le dôme conformément aux instructions du paragraphe III A Pour net toyer le réflecteur utilisez un chiffon doux et un liquide de n...

Страница 14: ...es pour examiner et lister les appareils de signaux visuels La première Norme UL pour la Sécurité est l UL1971 Dispositifs de Signaux pour les Malentendants Cette norme couvre les dispositifs de signaux visuels que comportent les systè mes d alarme d incendie pour alerter les malentendants La deuxième Norme UL pour la Sécurité est l UL1638 Appareils de Signaux Visuels Signaux d Urgence Mode Privé ...

Страница 15: ...el qu une sonnerie une sirène un haut parleur un voyant ou un affichage de texte émettant des signaux audibles tactiles ou visi bles ou leur combinaison En d autres termes ce dispositif ne doit pas être utilisé comme composant d un système d alarme d incendie commercial ...

Отзывы: