Chapter 3: Connecting the PA300-CN System
26
PA300-CN Siren Amplifier
2.
Use a multimeter to determine which source provides power when the vehicle key is in the
ignition position.
3.
See Figure 3.13. Connect the red lead from the control pad to the switched side of the vehicle
ignition harness.
Do not splice the red lead to the power leads for accessories.
Extend the lead
with 22 AWG leads or thicker.
Figure 3.13 Wiring for ignition power to control pad
22 AWG
BLACK
RED
CABLE ASSY.
P/N 17500063
TO +12 V
CONNECTION
ACTIVATED
BY IGNITION
TO –GND
4.
Connect the black lead from the control pad to negative ground. Extend the lead with 22 AWG
leads or thicker.
5
Insulate spliced leads with butt-spliced wire connectors. Fold and seal unused leads. Use wire ties
and hold-downs for strain relief.