Installation
Description, Specifications, Installation, Operation, and Service Manual
Federal Signal
www.fedsig.com
Figure 5 Typical Wiring Diagram
Electrical Connections
SHOCK HAZARD: Install the siren electrical system in compliance with local
electrical codes and NEC recommendations. Federal Signal also recommends
that all user-installed conduit connections enter from the bottom of the cabinet.
Disconnect all power and read all warnings at the beginning of this manual and
before making connections.
SHOCK HAZARD: The UV controller must be solidly connected to an earth ground.
If the siren is installed in a building, ground the system to a metallic object known
to be grounded. For pole mount installations, drive a metal rod or bar at least eight
feet into the ground, as close as practical to the base of the pole. Use a separate,
continuous 6 AWG or larger wire from the siren frame to ground and from the
cabinet of each siren control system to ground.