OPERATING INSTRUCTIONS

The fireplace control functions can be accessed in two ways:

-  Using the button control panel, located in the upper right-hand corner of the fireplace
-  Using the multifunction remote control

The main control panel is located at the top right corner on the front (see Figure 2). 

Read all instructions and warning prior to operating the appliance.

Ensure that all controls are in the

 “OFF”

 status before plugging the appliance into a properly grounded electrical 

outlet.  
This appliance is for use on 120 Volts.  The appliance has a 3-prong grounded plug (Figure 1.A).  If your electrical  

outlet has only 2 slots (Figure 1.B), you will have to use an adapter (Figure 1.C) to convert from the 3-prong 

power cord to a 2-slot receptacle.  The green grounding plug extending from the adapter must be securely 

connected to a permanent ground such as a properly grounded outlet box.  The adapter should only be used if a 

proper 3-slot receptacle is not available.  

NOTE:  Adapters are not allowed for use in Canada.

Figure 2

A 15 AMP circuit is required to operate this appliance.  If the breaker trips when the appliance is running, you may 

need to move the appliance to another location or unplug other appliances that are on the same circuit.  

!

Figure 1

Button Panel

ITEM# 384-15A-20-33A

MODEL# 16IN-32-110 

                                                                                        

Display Screen

Содержание ZHS-32-D

Страница 1: ...01 TOLL FREE 1 866 949 3838 EMAIL support easytop com cn PLEASE READ THIS MANUAL CAREFULLY FOR ELECTRIC FIREPLACE INSERT BEFORE INSTALL AND USE PLEASE DO NOT RETURN ANY PRODUCT TO STORE FOR ANY MISSIN...

Страница 2: ...e appliance turn all controls OFF then remove the plug from the electrical outlet 10 Connect to properly grounded outlets only 11 Do not insert or allow foreign objects to enter any ventilation or exh...

Страница 3: ...ong grounded plug Figure 1 A If your electrical outlet has only 2 slots Figure 1 B you will have to use an adapter Figure 1 C to convert from the 3 prong power cord to a 2 slot receptacle The green gr...

Страница 4: ...s feature can also be control with Remote Control Heater Control Figure 3 C The HEATER button controls the heat ON and OFF feature It can be used to switch the temperature reading on the Display Scree...

Страница 5: ...with FLAME HEATER TIMER button use this DOWN button to decrease Without press FLAME HEATER TIMER button press this button for the function of FLAME When FLAME HEATER TIMER is not activated this butto...

Страница 6: ...les Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Страница 7: ...ither Fahrenheit F or Celsius degrees C Without further operations the display screen display room temperature after around 6 seconds See Figure 4 A Once turn off the HEATER the blower will exhaust ai...

Страница 8: ...aust vents 4 Do not use abrasive cleaners or spray liquids on any part of the appliance 5 Periodic cleaning vacuuming of the fan heater unit is strongly recommended to ensure that no dirt or foreign o...

Страница 9: ...no 1 866 949 3838 3 Remove screws holding back panel in place and remove back panel Secure end of Flame wand back into the support bracket 4 Contact customer service center at toll free no 1 866 949 3...

Страница 10: ...l number of your EASY TOP product part number and defective part Register your product within ten days to ensure your warranty You must pay all expenses incurred in obtaining performance of any obliga...