TROUBLESHOOTING

 

WARNING

: If you smell gas: 

•  Shut off gas supply. 

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use any phone in your building. 

•  Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s 

 

           instructions. 

•  If you cannot reach your gas supplier, call the fire department. 

IMPORTANT

: Operating heater where impurities in air exist may create odors. Cleaning 

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., 

create fumes. These fumes may mix with combustion air and create odors.

 WARNING

: Make sure that power is turned off before proceeding.

 WARNING

: Turn off and let cool before servicing. Only a qualified service person should    

       service and repair heater.

 

CAUTION

: Never use a wire, needle, or similar object to clean ODS/pilot. This can dam

       age ODS/pilot unit.

Problem

Possible Cause

Corrective Action

When ignitor button is

pressed in, there is no 

spark at ODS/pilot

1. Ignitor electrode is positioned

 

wrong. Ignitor electrode is 

broken

2. Ignitor electrode is not

 

connected to ignitor cable.

3. Ignitor cable is pinched or

 

wet

4. Broken ignitor cable.

5. Bad piezo ignitor.

1. Replace electrode.

2. Replace ignitor cable

3. Free ignitor cable if pinched  

 

by any metal or tubing.

 

Keep ignitor cable dry.

4. Replace ignitor cable.

5. Replace piezo ignitor.

When ignitor button is 

pressed in there is a 

spark at ODS/pilot but no 

ignition.

1. Gas supply is turned off or

 

equipment shutoff valve is 

closed.

2. Control knob not fully 

pressed in while pressing 

ignitor button.

3. Air in gas lines when installed.

4. ODS / pilot is clogged.

5. Gas regulator setting is not correct.

6. Control knob not in PILOT position.

7. Depleted gas supply (propane).

1. Turn on gas supply or open 

equipment shutoff valve.

2. Fully press in control knob while

pressing ignitor button.

3. Continue holding down control

knob. Repeat igniting operation until 

air is removed.

4. Clean ODS/pilot (see 

Care

and Maintenance

, page 22) or 

replace ODS/pilot assembly.

5. Replace gas regulator.

6. Turn control knob to PILOT 

position.

7. Contact local propane/LP gas

company.

Содержание MD100TBE

Страница 1: ...y local codes This appliance is for use with the type of gas indicated on the rating plate only This appliance is not convertible for use with other gases This is an unvented gas fired heater It uses...

Страница 2: ...0 000 NG 28 000 LP Gas Type Using Natural Gas Using Natural Gas Using Natural Gas Pressure Regulator Setting 4 in W C 4 in W C 4 in W C Inlet Gas Pressure inches of water For purposes of input adjustm...

Страница 3: ...LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certa...

Страница 4: ...furniture 8 Always run heater with control knob at 1 2 3 4 5 locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monoxide may result 9 Do not u...

Страница 5: ...d plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale o...

Страница 6: ...se an unvented room heater as the primary heat source PREPARING FOR INSTALLATION Before beginning assembly or operation of the product make sure all parts are present Compare parts with package conten...

Страница 7: ...gate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are considered a pa...

Страница 8: ...logs BTU hr Gas water heater 30 000 BTU hr Other gas appliances BTU hr Vent free heater 26 000 BTU hr Total BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws comb...

Страница 9: ...the two spaces see options 1 and 2 Fig 1 You can also remove door into adjoining room see option 3 Fig 1 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for req...

Страница 10: ...ties such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc next to vinyl or cloth wall coverings WARNING Maintain the minimum clearances If you can provide greater clearance...

Страница 11: ...bracket from back panel Removing Front Panel of Heater 1 Remove 4 screws 2 screws on each side of the front panel 2 Pull front panel forward 3 Replace front panel when completed using the screws remo...

Страница 12: ...ake sure mounting bracket is level WARNING Maintain minimum clearances shown in Fig 3 If you can provide greater clearances from floor and joining wall 2 Mark screw locations on wall see Fig 6 Note Ma...

Страница 13: ...g Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Fig 9 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket Install...

Страница 14: ...egulator damage could occur PROPANE MODELS CAUTION Never connect heater directly to the gas supply This heater requires an external regulator not supplied Install the external regulator between the he...

Страница 15: ...aps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly Installation of Base Feet Before insta...

Страница 16: ...e heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug with wrench provided from natural gas inlet of regulator and install into LP i...

Страница 17: ...leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valv...

Страница 18: ...DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas...

Страница 19: ...hooting pages 23 through 25 Also contact a qualified service technician or gas supplier for repairs Until repairs are made light pilot with match If control knob does not pop up when released contact...

Страница 20: ...er senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The c...

Страница 21: ...me Pattern with Control Knob Set to High Flame 5 Fig 20 Correct Pilot Flame Pattern Fig 21 Incorrect Pilot Flame Pattern WARNING If yellow tipping occurs your heater could produce increased levels of...

Страница 22: ...um cleaner in the blow position If using compressed air in a can please follow the direc tions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the u...

Страница 23: ...ark at ODS pilot 1 Ignitor electrode is positioned wrong Ignitor electrode is broken 2 Ignitor electrode is not connected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Ba...

Страница 24: ...vice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 22 or...

Страница 25: ...r furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products H...

Страница 26: ...r Service or your dealer have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we w...

Страница 27: ...100 1 2 ODS Pilot Assembly NDD0308X600 MEDI 1 2 1 Thermocouple ND0803 6 1 2 2 Ignitor Electrode ND0807 1 3 Pressure Regulator RV83FI L S 4 9 1 4 Valve LHY 00 100 1 5 Plug PF120820 2 6 Grill Guard MEL2...

Страница 28: ...B3100 1 2 ODS Pilot Assembly NDD0308X800 MED 1 2 1 Thermocouple ND0803 8 1 2 2 Ignitor Electrode ND0807 1 3 Pressure Regulator RV83FI L S 4 9 1 4 Valve LHY 00 1 5 Plug PF120820 2 6 Grill Guard MEL3133...

Страница 29: ...EB5100 1 2 ODS Pilot Assembly NDD0308X800 MED 1 2 1 Thermocouple ND0803 8 1 2 2 Ignitor Electrode ND0807 1 3 Pressure Regulator RV83FI L S 4 9 1 4 Valve LHY 00 1 5 Plug PF120820 2 6 Grill Guard MEL513...

Страница 30: ...reinstallation are the expressed responsibility of the purchaser Any damage to the product by accident misuse improper installation or by affixing accessories not produced by the manufacturer are the...

Отзывы: