3.4.2 Setting up function codes quickly
-- Menu #0 "Quick Setup" --
Menu #0 "Quick Setup" in Programming mode allows you to quickly set up a fundamental set of function codes
that you specify beforehand. Whereas at shipment from factory, no function code is registered for Quick Setup,
you can add or delete some function codes using Menu #10 "User Setting." The set of function codes covered
by Quick Setup is held in the inverter (not the keypad). Therefore, if you mount your keypad onto another
inverter, the set of function codes held in the new inverter is subject to Quick Setup. If necessary, you may copy
the set of function codes subject to Quick Setup using the copy function (Menu #8 "Data Copying").
If you perform data initializing (function code H03), the set of function codes subject to Quick Setup will be reset
to the factory default.
The LCD screen transition from Menu #0 is the same as with Menu #1 "Data Setting."
Basic key operation
Same as the basic key operation for Menu #1 "Data Setting."
3.4.3 Checking changed function codes
-- Menu #2 "Data Checking" --
Menu #2 "Data Checking" in Programming mode allows you to check function codes (together with their data)
that have been changed. The function codes changed from the factory default are marked with . By selecting a
particular function code and pressing the
key, you can view or change its data.
The LCD screen transition from Menu #2 is the same as with Menu #1 "Data Setting," except for the different
screen listing function codes as shown below.
Changed
Function code data
Function code
Figure 3.12 Function Code List Screen
Basic key operation
Same as the basic key operation for Menu #1 "Data Setting."
3-13