Document Number:
MAN
– FDDOCAPSULE
Rev:
B
Revision Date:
12/09/2016
Page 7 of 37
©
2016 FDS Avionics Corp.
All Rights Reserved.
TECHNICAL SUPPORT
470-239-7421 or FDSAvionics.com
Installation Instructions
All cabin equipment, such as the do CAPSULE, should be installed on a non-essential bus and
have a dedicated circuit breaker. There are (8) #10 mounting locations on the unit: (4) on
the side flange and (4) on the bottom flange (Refer to the Technical Drawing on page 22). FDS
Avionics recommends using at least (4) #10 screws on the bottom flange or the side flange.
Mounting the unit with (2) #10 screws on each side is also an acceptable method of mounting
the unit. The unit requires adequate airflow to prevent overheating. The top and the side
ventilation holes must be unobstructed to allow the forced air cooling of the system to operate.
FDS Avionics recommends one inch of clearance to allow adequate intake and exhaust of air.
Video Wiring Suggestions
For balanced signals on twisted pair cable, all shields should be grounded to the connector at
the source, and floating at the display.
Avoid routing video wiring parallel to:
AC wiring
Strobe wiring
DC motor supply cables
Inverter cabling
Or any other potential noise source.