CAUTION!
The unit is designed for indoor use. Do not expose this unit to rain, snow or
liquids of any type.
CAUTION!
To reduce risk of injury, only use qualified batteries from qualified distributors or
manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or
overdue batteries. Please check the battery type and date code before installation to avoid
damage and injury.
WARNING!
It's very important for system safety and efficient operation to use appropriate
external battery cable. To reduce risk of injury, external battery cables should be UL certified
and rated for 7
5°
C or higher. And do not use copper cables less than 10AWG. Below is the
external battery cable reference according to system requirements.
Table 1 Minimum Recommended Battery Cable Size versus Length
Model
Typical Amp.
1 meter (one-way)
Dia-mm
1200VA
75 A
AWG 3
5.8272
2400VA
75 A
AWG 3
5.8272
Table 2 External Battery Cable Size Reference
AWG
Dia-mm
Ohms/Kft
0000(4/0)
11.684
0.049
000(3/0)
10.405
0.0618
00(2/0)
9.2657
0.0779
0(1/0)
8.2513
0.0983
1
7.348
0.1239
2
6.5436
0.1563
3
5.8272
0.197
4
5.1893
0.2485
5
4.6212
0.3133
CAUTION!
Do not disassemble the inverter. Contact with the qualified service center when
service or repair is required.
WARNING!
Provide ventilation to outdoors from the battery compartment. The battery
enclosure should be designed to prevent accumulation and concentration of hydrogen gas at
the top of the compartment.
CAUTION!
Use insulated tools to reduce the chance of short-circuit when installing or working
with the inverter, the batteries, or other equipments attached to this unit.
CAUTION!
For battery installation and maintenance, read the battery manufacturer's
installation and maintenance instructions prior to operating.
Personnel Precaution -
CAUTION!
Careful to reduce the risk or dropping a metal tool on the batteries. It could spark
or short circuit the batteries and could cause an explosion.
CAUTION!
Remove personal metal items such as rings, bracelets, necklaces, and watches
when working with batteries. Batteries can produce a short circuit current high enough to
make metal melt, and could cause severe burns.
CAUTION!
Avoid touching eyes while working near batteries.
CAUTION!
Have plenty of fresh water and soap nearby in case battery acid contacts skin,
clothing, or eyes.
CAUTION!
NEVER smoke or allow a spark or flame in vicinity of a battery.
CAUTION!
If a remote or automatic generator start system is used, disable the automatic
starting circuit or disconnect the generator to prevent accident during servicing.
4. Specifications
MODEL
1200
2400
CAPACITY
1200 VA / 720 W
2400 VA / 1440 W
INPUT
Voltage
230 VAC
Voltage Range
90-280 VAC
OUTPUT
Voltage Regulation (Batt. Mode)
+/-10%
Transfer Time
20 ms typical
Waveform
Simulated Sine Wave
BATTERY
Battery Voltage
12 VDC
24 VDC
Floating Charge Voltage
13.7 VDC ± 2%
27.4 VDC ± 2%
Maximum AC Charge Current
10 A or 20 A
SOLAR CHARGER
Charging Current
50 A max.
Maximum PV Array Open Circuit Voltage
40 VDC
60 VDC
PHYSICAL
Dimension (DxWxH) mm
300 X 360 X 88
Net Weight (kgs)
6.3
7.6
5. Installation
NOTE:
Before installation, please inspect the unit. Be sure that nothing inside the package is
damaged.
Connect to Utility and Charge
Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected
external battery even though the unit is off.
Connect External Battery
Step 1-
Take away the cover of external battery terminal.
Step 2
- Following battery polarity guide printed near the battery terminal!
Place the external battery cable ring terminal over the battery terminal.
RED cable to the positive terminal (+);
BLACK cable to the negative terminal (-).