ST100A Series Flow Meter
MAINTENANCE
Fluid Components International LLC
91
Lithium Battery Replacement
A 3-volt lithium coin cell battery powers the ST80/ST80L real time clock (RTC). Typical service life of the battery is two years. Replace the
battery every two years with the CR2450N coin cell battery listed in
Table 27 – Lithium Coin Cell Battery Summary
Qty
FCI Assembly P/Ns
Description
Mfgr. P/N
FCI P/N
1
025740-01 (Main Board)
3V Lithium battery type CR2450N,
540 mAh, temperature range: -40 °C
– +85 °C, Manufacturer: Renata
CR2450N
022038-01
Caution:
Use only the recommended industrial spec battery listed above. A consumer grade battery will not fit well in the
holder and is prone to leakage or reduced performance or both when used in an industrial environment.
Disassemble the electronics to access the battery.
below gives an exploded view of the instrument. Remove the instrument’s
blind lid (refer to instructions in
) and follow the disassembly instructions below (skip steps 3
through 6 if unit has no display). The number callouts in the figure correspond to the numbered steps below.
Warning:
Make sure system power is OFF before replacing the battery.
1. Remove all user cabling/wiring from the instrument connectors, and then pull all cable/wiring from the cable/wiring ports.
2. Using a 3 mm hex key, remove 2X M4 socket head cap screws securing electronics/cage assembly to housing, and 1X M4 socket
head cap screw securing ground wire to housing. Remove electronics/card cage assembly from housing.
3. Separate bezel/HMI sensor assembly from the cage by pulling straight out.
4. Remove HMI jumper cable from the pin socket at the top the bezel/HMI sensor assembly (
).
5. Remove 3X 18-8 drive screws securing the display to the cage. Carefully pull the display assembly away from the cage to expose the
FFC (flat flexible cable) cable.
6. Open the FFC cable connector on the main board: Pull the FFC connector lock tab out and then up (away from the board). Once the
lock tab is opened, pull the FFC cable from the connector. Refer to the FFC connector detail in
Carefully set aside the fully
detached display assembly.
7. Remove 2X nylon snap rivets securing electronics assembly to the cage, and then slide electronics assembly out to clear the cage.
8. Pull the lithium coin battery from its holder on the main board.
9. Install replacement battery type CR2450N in the coin cell holder with the positive (+) side facing the main board connectors. Use the
replacement battery listed in
above.
10. Reassembly is reverse of removal. (Make sure FFC display cable is fully inserted and square in connector before pushing the lock tab
back into closed position.)
Содержание ST100A Series
Страница 1: ......
Страница 42: ...INSTALLATION ST100A Series Flow Meter 34 Fluid Components International LLC This Page Intentionally Left Blank ...
Страница 114: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 106 Fluid Components International LLC This Page Intentionally Left Blank ...
Страница 115: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 107 ...
Страница 116: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 108 Fluid Components International LLC ...
Страница 117: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 109 ...
Страница 118: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 110 Fluid Components International LLC ...
Страница 119: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 111 ...
Страница 120: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 112 Fluid Components International LLC ...
Страница 121: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 113 ...
Страница 122: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 114 Fluid Components International LLC ...
Страница 123: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 115 ...
Страница 124: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 116 Fluid Components International LLC ...
Страница 125: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 117 ...
Страница 126: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 118 Fluid Components International LLC ...
Страница 127: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 119 ...
Страница 128: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 120 Fluid Components International LLC ...
Страница 129: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 121 ...
Страница 130: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 122 Fluid Components International LLC ...
Страница 131: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 123 ...
Страница 132: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 124 Fluid Components International LLC ...
Страница 133: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 125 ...
Страница 134: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 126 Fluid Components International LLC ...
Страница 135: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 127 ...
Страница 136: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 128 Fluid Components International LLC ...
Страница 137: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 129 ...
Страница 138: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 130 Fluid Components International LLC ...
Страница 139: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 131 ...
Страница 140: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 132 Fluid Components International LLC ...
Страница 141: ...ST100A Series Flow Meter APPENDIX A DRAWINGS Fluid Components International LLC 133 ...
Страница 142: ...APPENDIX A DRAWINGS ST100A Series Flow Meter 134 Fluid Components International LLC ...
Страница 145: ...ST100A Series Flow Meter APPENDIX B ADDITIONAL INFORMATION Fluid Components International LLC 137 ...
Страница 146: ...APPENDIX B ADDITIONAL INFORMATION ST100A Series Flow Meter 138 Fluid Components International LLC ...
Страница 147: ...ST100A Series Flow Meter APPENDIX B ADDITIONAL INFORMATION Fluid Components International LLC 139 ...
Страница 148: ...APPENDIX B ADDITIONAL INFORMATION ST100A Series Flow Meter 140 Fluid Components International LLC ...
Страница 149: ...ST100A Series Flow Meter APPENDIX B ADDITIONAL INFORMATION Fluid Components International LLC 141 ...
Страница 150: ...APPENDIX B ADDITIONAL INFORMATION ST100A Series Flow Meter 142 Fluid Components International LLC ...
Страница 151: ...ST100A Series Flow Meter APPENDIX B ADDITIONAL INFORMATION Fluid Components International LLC 143 ...
Страница 152: ...APPENDIX B ADDITIONAL INFORMATION ST100A Series Flow Meter 144 Fluid Components International LLC ...
Страница 158: ...APPENDIX C GLOSSARY ST100A Series Flow Meter 150 Fluid Components International LLC This Page Intentionally Left Blank ...
Страница 167: ...ST100A Series Flow Meter APPENDIX E CUSTOMER SERVICE Fluid Components International LLC 159 ...
Страница 168: ...APPENDIX E CUSTOMER SERVICE ST100A Series Flow Meter 160 Fluid Components International LLC ...