VERTUS MLA 801A

4

GENERAL FEATURES

VERTUS MLA 801A

>  8-way active HF Line Array Column in bass reflex
>  Digital / mechanical directivity aiming
> Control panel with XLR input and XLR link, volume, preset, 7 step angle aiming, ground-lift, RJ45 in /out  for RS-485 network, 

Euroblock connector for in/out audio 

> 8 x 0,75" B&C neodymium drivers with 1" voice coil
> 1.8kHz - 20kHz frequency response
> 8 Class D 50W RMS amplifiers for a total of 400W  power
> Completely controllable directional features, through control switches on the back panel or through PC software and dedicated 

network

>  Extruded-aluminum powder coated cabinet with superior latching system as well as inferior
> Combined aiming digital / mechanical full-range system from +5° to -25° with included lobe width between 5° an 25° / 40°
> 8 hybrid stepped motor controlled by a microprocessor for the mechanical aiming of wave guides
> PC / Slave function for aiming control via PC or other MLA module
>  Frontal status led
> Possibility of mounting on subwoofer  or of wall-mount installation with the supplied bars.

Содержание MLA 608A

Страница 1: ...I F D UK ENGLISH ...

Страница 2: ... 9 WARNING IMPORTANT SAFETY INSTRUCTIONS PRECAUTIONS INTRODUCTION GENERAL FEATURES POWER SUPPLY CONNECTORS INSTALLATION MODE CONTROLS AND FUNCTIONS CONNECTION OF LOUDSPEAKERS USB RS485 CONVERTER CONNECTION EXAMPLES TECHNICAL SPECIFICATIONS DIMENSIONS ...

Страница 3: ...CK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING IMPORTANT SAFETY INSTRUCTIONS ...

Страница 4: ...2 ...

Страница 5: ... response 6 Class D 250W RMS amplifiers with three switch mode power supplies for a total of 1500W power Completely controllable directional features through control switches on the back panel or through PC software and dedicated RS485 network Extruded aluminum powder coated cabinet with superior latching system as well as inferior Digital full range aiming from 5 to 25 with included beamwidth bet...

Страница 6: ...l of 400W power Completely controllable directional features through control switches on the back panel or through PC software and dedicated network Extruded aluminum powder coated cabinet with superior latching system as well as inferior Combined aiming digital mechanical full range system from 5 to 25 with included lobe width between 5 an 25 40 8 hybrid stepped motor controlled by a microprocess...

Страница 7: ... manufactured by specialized staff using a H05VV F cable with 2 5 sq mm section and plug with rated current 20A where 20A is the maximum rated current of the powercon connector see example 2 The power cord has to be assembled by specialized staff complying with national plant engineering regulations Protect the mains cable when it is not used In case of chain connection connect the cable to the gr...

Страница 8: ... maximum current values shown in picture 1 and 2 THE CABLEAND THE PLUG MUST HOLD THE UL OR CSA CERTIFICATION The power cord has to be assembled by specialized staff complying with national plant engineering regulations Protect the mains cable when it is not used In case of chain connection connect the cable to the grey outlet of the first speaker and to the blue outlet of the second one and so on ...

Страница 9: ...7 ...

Страница 10: ...DIMENSIONS MLA 608A 8 ...

Страница 11: ...DIMENSIONS MLA 801A 9 ...

Страница 12: ...these instructions or failure to check the safety factor of all components involved in the installation system The loudspeakers of the VERTUS MLA series must be installed by suspension using wall brackets Besides the main suspension system all flying speakers in theatres indoor stadiums or in several other work and or leisure facilities shall be provided with an additional independent safety syste...

Страница 13: ...1 2 CONNECTION OF TWO COLUMNS fig A 11 INSTALLATION MODE Connect the two satellites to one another as shown in picture A For wall mounting use adequate anchor slots ANCHOR SLOTS ...

Страница 14: ...LATION MODE To fasten the two columns onto the wall use the upper and lower brackets The central brackets must be removed and one of them used as safety fastening see fig B CAUTION holes C let loose by the moving bracket must absolutely be closed with the relevant screws ...

Страница 15: ...sted in the table to properly program the system VOLUME Adjusts the volume of the single loudspeaker PRESET Selects 4 presets each corresponding to a different equalization based on the installation to be performed FOH for installations in open field or WALLfor fixed installations and the use made of the system FLAT for music or VOCALfor speech RESET allows you to reset the internal memory that co...

Страница 16: ...pening angle of the sound beam follow the limits listed in the table to properly program the system VOLUME Adjusts the volume of the single loudspeaker PRESET Selects 4 presets each corresponding to a different equalization based on the installation to be performed FOH for installations in open field or WALL for fixed installations and the use made of the system FLAT for music or VOCALfor speech H...

Страница 17: ...TWORK IN using a standard Ethernet cable Connect the loudspeakers in succession with Ethernet cables from NETWORK OUT to NETWORK IN and place the relevant RJ45 bridge on the output of the last speaker The succession of the speakers starting with the first one identifiable on the software as the speaker adjacent to the FRAME must follow the order of the system as designed on the PC The software doe...

Страница 18: ...ORK IN with a standard Ethernet cable Connect the loudspeakers in sequence using Ethernet cables NETWORK OUT to NETWORK IN and place on the last loudspeaker output the proper RJ45 bridge provided together with the MLA801A sound diffuser The sequence of loudspeakers shall match the order of the system programmed on the PC starting from the first loudspeaker detected by the software as adjacent to t...

Страница 19: ...STAND ALONE 17 CONNECTION EXAMPLES CONTROL FROM PC ...

Страница 20: ...PUT CONNECTORS POWER CORD NET DIMENSIONS WxHxD NET WEIGHT TRANSPORT DIMENSIONS WxHxD TRANSPORT WEIGHT way watt watt watt 6dB inch inch dB H x V kOhm kHz VA ft inch inch lb lb 8 6 8 x 40 6 x 230 8 x 50 6 x 250 8 x 100 6 x 500 1 8kHz 20kHz 60Hz 2kHz 6 x 8 2 coil 8 x 0 75 1 coil 135 139 133 137 90 digital mechanical controlled 22 22 1 8 1 8 300 1350 XLR with loop XLR with loop Sub Out 16 4 16 4 9 5 x...

Страница 21: ...CODE 35546 12 2011 ...