Security Sub-menu
– this sub-menu allows the User to set the parameters shown, lock the
DLM26 and set a Password therefore limiting the unit's functions and controls to those who have
access to the appropriate Password.
Press ENTER and then use the NAV/Param.1 to scroll between options.
−
Show Parameter:
Pressing ENTER from the above menu will access the “Show Parameter”
Sub Menu
Press ENTER again and use the Param.2 or Param.3 encoders to scroll between the “be shown”
and “not be shown” options. An asterisk will highlight which option is selected.
Choosing the “be shown” option means that once the unit is locked, you cannot access
parameter editing features, but they will be displayed on the LCD screen.
Choosing the “not be shown” option means that once the unit is locked, the parameters will
not be shown at all. With this option, when trying to access a parameter, the following screen
message will appear:
−
Lock Unit:
this sub-menu allows the user to lock the device so no parameters can be edited
or modified.
When the Unit is in an unlocked condition, all parameters will be available for editing. When
you select On, all parameters will be locked and are not available for editing.
When you select lock from the menu, the unit will be locked and the lock menu automatically
exited. The screen will revert to the “Default” showing the current XOVER configuration and
the preset selected and beside the preset’s name a “keylock” icon indicating that the DLM26 is
locked.
UTILITY MENU
-- Security Utilities --
SECURITY UTILITY
-- Show Parameter --
Parameter will
not be shown *
SECURITY UTILITY
-- Lock Unit --
Lock Unit
Lock : On *
Содержание DLM26
Страница 66: ......