background image

Warning:

To be installed and/or used in accor-
dance  with  appropriate  electrical
codes and regulations.

Warning:

To  avoid  fire,  electrical

shock  and/or  electrocution  turn
power OFF at the circuit breaker be-
fore wiring. 

Caution:

Wire devices in accordance

with the NEC. 
If  you  are  not  sure  about  existing
conductor wires, color coding, polar-
ity  and  circuit  feed  contact  a  li-
censed electrician.

MS10166

Surface Mount Box

IMPORTANT:  Please read carefully the following instructions before beginning. 

Product configuration may vary.

Detach the box base from the body
by removing the screws located at
all four corners. 
You can also remove the two top
faceplates for more flexibility on the
wiring related jobs. To do so,  gen-
tle press the small screw caps on
one side and remove it. Remove
the screws to separate the
yoke/faceplates from the box body.
(See exploded view)

Exploded view

The box base has screw holes at all four
corners, plus, two screw holes that match
the holes pattern present on single and two
gang outlets boxes. 

Option 1: Install an “Old
Work type single gang out-
let box” flush with the sur-
face.   Attach the conduit to
the outlet box to feed the
line voltage wires.  Low
voltage cables   do not re-
quire conduits.

Option 2: Install an
Old Work type two
gang outlet box with 

Option 3: Feed the MS box compartments by conduits, elbows etc. 
There are no knockouts in the base of this box.  

Wood surfaces / Tables / Raised floors

barrier. The barrier
divides the box in
two compartments. 

Keep the screws in a safe place for later use.

MS10166 - Mounting Base

1/2

DISCLAIMER - (Worldwide)
FBS FLOOR BOX SYSTEMS MAKE
NO WARRANTIES OR REPRESEN-
TATIONS, WHATSOEVER, EXPRESS
OR IMPLIED, AS TO THE MER-
CHANTABILITY, FITNESS OR SUIT-
ABILITY OF THIS PRODUCT. 

Installer/Buyer of this product must ver-
ify the 

suitability or approval of this

product for the specific use with the
local codes and/or authorities hav-
ing jurisdiction in the area where
the product will be installed.

Use one compartment to feed the line
wires and one for the low voltage appli-
cations. 

FBS FLOOR BOX SYSTEMS

25060 Hancock Ave

STE 103-125

Murrieta, CA 92562

1-800-216-8307

-Installation Guide

-

Questions?

1.800.216.8307

www.FloorBoxSystems.com