MX

-500

 Dual 

Technology 

Motion 

Sensor 

 Installation 

Instructions

T

T

Step 1

Separate the sensor housings and remove

Printed Circuit Board (PCB).

Use a small screwdriver to unfasten the hous-

ing latch and separate the sensor housings.

Push outward on the PCB latch to lift the PCB

out of the housing.

Step 3

Wire the sensor.

Observing  the  proper  polarity,  wire  the  unit  as

shown in the illustration below, use 1.02 to 0.64 mm

(18 to 22 AWG) wire.

Step 2

Mount the sensor.

Break out the mounting/wiring knockouts and

mount the sensor in an appropriate location.

An ideal location meets the following objectives:

Allows  a  clear  line-of-sight  to  all  areas  to

protect.

Does not directly face windows.

Avoids close proximity to moving machinery,

fluorescent lights, and heating/cooling

sources.

NOTE:

    maximum  range  is  obtained  at  a

mounting height of 2.3 m (7’6”).

Knockout

Housing

latch

PCB latch

FRONT HOUSING

REAR HOUSING AND PCB

Terminal Block

TB1

PCB

LED

(DS1)

LED  Enable

(Cut  LED  enable

jumper J1 to

disable  LED)*

Step 4

Walk-test the sensor.

After returning the PCB to the rear housing,

reassemble  the  sensor  housing.  Apply

power  to  the  sensor  and  begin  walk-test

when the red LED is off.

Walk across the detection area at the ranges

to be covered. The red LED should indicate

an alarm condition after 2 to 4 normal steps.

When there is no motion in the detection

area the LED should be off.

Terminal Block

TB2

Alarm

500 mA

30 VDC

Power

25 mA

7.5-16 VDC

(UL: 8.9-14.5 VDC)

TB1

Tamper

50 mA

24 VDC

TB2

* R