77X INSTALLATION & OPERATION MANUAL
771/772/773/774 MODELS
42
Error #051, 052, 053, 054: Safety Fill Error
A barrel filled continuously for more than two minutes.
Error #061, 062, 063, 064: Beater Low Error
A beater motor stalled during operation.
Error #070: Compressor Ran Too Long
The compressor ran continuously for more than 90 minutes.
Error #081, 082, 083, 084: High Barrel Pressure
The pressure on a barrel exceeded 55 PSIG (379 kPag).
Error #090: Hot Product Detected
The system shut down because product in a barrel exceeds 90° F (32.2
°
C) for 200 seconds or 110° F (43.3
°
C) for 50
seconds depending on dispenser software.
Error #111, 112, 113, 114: Motor Failure
The beater motor is not operating.
1
Run the fill diagnostic sequence to determine the reason for the failure.
1
Check the brix in the barrel. If low, check the brix at the sample valve and adjust if needed. Drain
and refill the barrel.
2
Check the fault code history for multiple sold-out errors within a short period. This can mean that
the BIB connector or syrup pump has a suction leak. Fix if necessary.
3
Run the beater circuit diagnostic if a component failure is suspected.
1
Is the location an extreme volume venue such as a festival? If so, contact FBD service for
instructions on adjusting the timer.
2
Run the refrigeration diagnostic sequence to determine the reason for the failure.
1
Dispense a drink to reduce the barrel pressure. The dispenser will refreeze if set to the ON mode.
2
Run the fill diagnostic if a failed component is suspected.
3
Check the “Active Charge” regulator located on the product header to ensure it is set at 30
PSIG (207 kPag). All barrels should be fully depressurized before checking the active charge.
On non-DCC dispensers, use a tire gauge to check the pressure.
On DCC dispensers, use the pressure displayed on the LCD Screen.
1
Check the return temperature sensor for proper operation.
2
If hot product was detected, call FBD for technical assistance.
1
Run a beater circuit diagnostic to determine the problem or refer to error #58X in this manual.
2
Check to make sure the beater motor is plugged in.
Содержание 77 Series