Operation
BOMAG
27
BT 60/4, BT 65/4
Fig. 17
l
Open the choke (Fig. 17) 3 to 6 seconds after
the engine has started running.
Fig. 18
l
Set the throttle lever (Fig. 18) to position "MIN"
and let the engine run warm for 1 to 2 minutes.
Note
i
Once the engine has warmed up you can start to
work with the tamper.
Starting under cold weather conditions
l
If the engine stops again after approx. 3 to 5
seconds, close the choke again and repeat the
starting process.
Engine oil level too low
Fig. 19
The engine does not start if the oil level is too low.
This is indicated by the engine oil level warning
lamp (Fig. 19) when operating the recoil starter.
l
Check the engine oil level, fill up if necessary.
l
Repeat the starting procedure.
Engine "drowned"
Note
i
When the choke is closed and the starter rope is
pulled several times, the engine draws in too much
fuel and will probably not start.
Remedy
l
Set the engine stop switch to position "OFF"
(fuel valve closed).
l
Open the choke.
l
Set the throttle lever to full speed position.
l
Operate the starter rope 10-20 times.
l
Set the engine stop switch to position "ON"
l
Operate the starter rope once again.
Note
i
If the engine does not start after 3 to 5 attempts
l
Close the choke.
l
Operate the starter rope once again.
Note
i
If the engine does not start after 3 to 5 attempts
540240