Special instructions
4812158701_G.pdf
2019-10-01
with a rubber band. This is to avoid high pressure
water entering the vent hole in the filler cap. This could
cause malfunctions, such as the blocking of filters.
Place a plastic bag over the exhaust pipe and secure
with a rubber band to avoid water in the muffler.
Never aim the water jet directly at the fuel tank
cap, or into exhaust pipe. This is particularly
important when using a high-pressure cleaner.
Never aim the water jet directly at the fuel tank
cap, or into exhaust pipe. This is particularly
important when using a high-pressure cleaner.
Fire fighting
If the machine catches fire, use an ABC-class powder
fire extinguisher.
A BE-class carbon dioxide fire extinguisher can also
be used.
Roll Over Protective Structure (ROPS), ROPS
approved cab
If the machine is fitted with a Roll Over
Protective Structure (ROPS, or ROPS approved
cab) never carry out any welding or drilling in
the structure or cab.
If the machine is fitted with a Roll Over
Protective Structure (ROPS, or ROPS approved
cab) never carry out any welding or drilling in
the structure or cab.
Never attempt to repair a damaged ROPS
structure or cab. These must be replaced with
new ROPS structure or cabs.
Never attempt to repair a damaged ROPS
structure or cab. These must be replaced with
new ROPS structure or cabs.
Welding
When carrying out welding on the machine, the
battery must be disconnected and the
electronics disconnected from the electrical
system.
When carrying out welding on the machine, the
battery must be disconnected and the
electronics disconnected from the electrical
system.
If possible, remove the part(s) to be welded
from the machine.
If possible, remove the part(s) to be welded
from the machine.
Battery handling
When removing batteries, always disconnect the
negative cable first.
When removing batteries, always disconnect the
negative cable first.
When fitting batteries, always connect the
positive cable first.
When fitting batteries, always connect the
positive cable first.
12
Содержание DYNAPAC CA5000
Страница 2: ......
Страница 12: ...e 4812158701_G pdf 2019 10 01...
Страница 16: ...Introduction 4812158701_G pdf 2019 10 01 4...
Страница 22: ...Safety Optional 4812158701_G pdf 2019 10 01 10...
Страница 26: ...Special instructions 4812158701_G pdf 2019 10 01 14...
Страница 70: ...Machine description 4812158701_G pdf 2019 10 01 58...
Страница 104: ...Operating instructions Summary 4812158701_G pdf 2019 10 01 92...
Страница 106: ...Preventive maintenance 4812158701_G pdf 2019 10 01 94...