background image

8

FAVERO Electronics

 - 0259-0902A Assioma user manual _Rev21 - EN-IT-DE

ENGLISH

8.3. 

Cleat release force adjustment

Before starting to ride, try to release the shoe several times and make sure that 

the release force is suitable.

the 

correct direction

 to unclip is external to the bike. 

9. 

Bike computer configuration

9.1.  Pairing assioma to the bike computer

the 

pairing procedure associates 

assioma

 to the bike computer to start the radio 

communication between the two devices. 

 

Please 

read the bike computer manual to learn how 

it 

performs the search and pairing 

of a power sensor. Make sure that 

assioma

 is switched on before proceeding 

(Chap. 5)

.

 

each 

assioma

 has a unique 5-digit identification number (ANT+ ID) written on the 

packaging.  This number identifies 

assioma

 in the list of devices which can be paired

with 

the bike computer

.

 

Bike 

computers require that only the left pedal be paired. The left pedal will transmit 

also the data collected by the associated right pedal. 

 

on 

Bluetooth bike computers and other devices with Cycling Power Profile (CPP), the 

left pedal can be recognized by an L that follows the identification number

.

The spring tension can be adjusted using the 

screw shown in the picture. To increase the 

tension turn clockwise; 

to decrease the tension, turn counter-clockwise.

Use a 3 mm wrench (not supplied).

Increase

Decrease

Adjust the tension 

of the spring depending

on your needs.

Содержание 772-01

Страница 1: ...1 User manual 1 EN Manuale d uso 18 IT Bedienungsanleitung 35 DE Art 772 01 ASSIOMA UNO cycling power meter Art 772 02 ASSIOMA DUO cycling power meter ...

Страница 2: ...t release force adjustment Chap 8 5 Bike computer configuration Chap 9 Pairing Assioma to the bike computer Chap 9 1 Configuration of power fields Chap 9 2 Crank arm length Chap 9 3 6 Manual and automatic calibration zero offset Chap 10 Very Important 7 Using Assioma for the first time on road or rollers Chap 11 Manual calibration is required at first installation and any time Assioma is moved bet...

Страница 3: ...ing shoe position check and cleat release force adjustment 6 9 Bike computer configuration 8 10 Manual and automatic calibration zero offset 9 11 Using Assioma for the first time on road or rollers 10 12 Battery charge 10 13 Transforming Assioma UNO into Assioma DUO 12 14 Removing the pedals 12 15 Reinstalling the pedals on another bicycle 12 16 Compatible bike computers 12 17 App compatibility 13...

Страница 4: ... measure the force applied to the pedal during the pedal stroke This pedal includes the function of cadence meter and can calculate the power of a single leg in real time sending it to the bike computer It is provided with a rechargeable battery designed to guarantee an operating time of at least 50 hours during many years of use Therefore there are no openings with gaskets for the replacement of ...

Страница 5: ...nect it to the supplied battery charger for a few seconds to switch it on Follow the same procedure if Travel mode has been activated from the Favero Assioma app If the LEDs do not blink charge the battery as indicated in Chap 12 For LED behavior read Chap 18 6 Activating Assioma Assioma must be activated to measure the power and cadence If it is not activated such measuring will not be performed ...

Страница 6: ...age it This operation would invalidate the warranty If necessary use 1 or 2 washers to ensure a free space of at least 1 mm between the sensor and crank arm Ifacadencesensorisfittednearthepedal removeittoavoidanycontactwiththeAssiomasensor 7 2 Tightening the pedals Before tightening the pedals apply a thin layer of grease to the pedal axle thread Tighten the pedal to the crank arm using the suppli...

Страница 7: ...d cleats red cleats float 6 or original LOOK Kéo cleats The use of non original LOOK Kéo compatible cleats may be unsuitable and any damage to the product will not be covered by the warranty To fix the cleats use the supplied screws and washers Align the cleat in the preferred position and tighten the screws with a tightening force of 4 6 Nm 3 4 5 ft lb as for most of the cleats on the market Blac...

Страница 8: ...starting to ride check that the distance between the shoe and the sensor is at least 2 mm Do not use the product if the sensor is in contact with the shoe the shoe cover or the cleat as it can be damaged and this would invalidate the warranty If the distance between the sensor and the shoe is less than 2 mm move the cleat to the most appropriate position or insert spacer Art 771 45 between the cle...

Страница 9: ...ioma is switched on before proceeding Chap 5 Each Assioma has a unique 5 digit identification number ANT ID written on the packaging This number identifies Assioma in the list of devices which can be paired with the bike computer Bike computers require that only the left pedal be paired The left pedal will transmit also the data collected by the associated right pedal On Bluetooth bike computers a...

Страница 10: ...lease refer to the bike computer manual to learn how to set the crank arm length If the crank arm length cannot be set on the bike computer set this parameter using the Favero Assioma App Do not set the crank arm length via the Favero Assioma App if the bike computer already allows this operation the set value would be overwritten 10 Manual and automatic calibration zero offset Each Assioma sensor...

Страница 11: ...onfirmation message or a 0 zero Repeat the operation if an error occurs Sometimes manual calibration is slowed down or prevented if other ANT sensors e g cardio band cadence sensor are enabled but switched off on the bike computer as the bike computer searches them but cannot find them In this case it is necessary to switch them on or disable them temporarily on the bike computer 11 Using Assioma ...

Страница 12: ...8 hours To charge the batteries follow the procedure below for each sensor Connect the battery charger supplied to an electrical socket Connect the USB cable supplied to the battery charger Insert the micro USB connector into the magnetic connector see the picture If the sensor contacts are wet or dirty dry or clean them with a dry cloth Connect the magnetic connector to the pedal as indicated in ...

Страница 13: ...CKWISE facing it Unscrew the RIGHT pedal COUNTER CLOCKWISE facing it 15 Reinstalling the pedals on another bicycle Any time the pedals are moved from one bicycle to another manual calibration must be performed Chap 10 Once the pedals are reinstalled the power and cadence data displayed on the bike computer are no longer reliable until Assioma performs an internal self calibration Assioma self cali...

Страница 14: ...y charging has been completed 19 Inspection and maintenance Carefully inspect the product before starting a cycling session check all parts for damage cracks loose parts and signs of wear Do not use the product unless you have carefully checked and replaced any worn or damaged parts If the product is not in perfect conditions its use may be the cause of accidents damage to things and or injuries t...

Страница 15: ...thereisanycontactbetweentheshoe orshoecover andthesensor Chap 8 2 Cadence and power are not displayed Activate the product Chap 6 Configure the bike computer Chap 9 Perform manual calibration Chap 10 Ride uniformly to allow self calibration Chap 11 The LEDs do not switch on Fully charge the product Chap 12 Make sure that the battery charger and the cables supplied are correctly working Chap 12 or ...

Страница 16: ...is a registered trademark of Favero Electronics LOOK and Kéo trademarks belong to LOOK Cycle International All other trademarks and registered trademarks are the property of their corresponding owners 23 Warranty All the information related to the product warranty are contained in the Warranty leaflet supplied with Assioma or which can also be downloaded from the cycling favero com website 24 Tech...

Страница 17: ...ing 9 16 20 TPI Bearings no 3 sealed cartridge bearings Operating temperature 10 60 C Battery charging temperature 5 40 C Protection degree IP67 Certifications CE FCC PSE AUS NZ KC RoHS ANT BLE Compatible cleats Favero red cleats art 771 42 black cleats art 771 40 LOOK KEO Cleat original only Max cyclist weight 120 Kg 1 Warranty 2 years This product has been designed for weights no higher than tho...

Страница 18: ...ion for left pedal Counter clockwise closing direction for right pedal Use a 9 mm socket wrench CH9 with max 13 mm outer diameter End cap 2 3 Nm M6 nut 8 10 Nm 6 13 bearing 10 15 bearing Left pedal body Art 772 60 Right pedal body Art 772 61 Oil retainer Grease the axle with lithium grease Assioma sensor on left axle Art 772 64 Bearing set M6 nuts oil seal end caps washers Art 772 72 Assioma senso...

Отзывы: