User manual AD CM M
Page 9 of 20
2
Set-up and installation of AD CM M1S
This section refers to all functions offered by the stepper motor driver type AD CM M1S. The set-up of the M2S
and M3S version is the same, relatively to the functions of the M1S, but offers some additional functionalities.
2.1
Block Diagram
Host
GND
STY
GND
INH
Clock
Direction
Phase B
Phase A
M
Translator
2.2
Location of Components
0
1
2 3
4 5 6
7
8
9
ABC
DE
F
F/H
DIR
Bu
s
y
OPO
F/H
DIR
Bu
s
y
OPO
G
N
D
V
+
1
M
O
T
O
R
4
•
COMMAND, screw-type terminal, 12-positions
•
MOTOR A, locking connector, Molex 4-pins miniature
•
POWER MOTOR, screw type terminal, 6-positions
•
Switch, manual switch, 3-pins
•
Current selection, screw type potentiometer, 16-positions
•
Status LED “busy” indicator
For Pin-out and functional explanations, please see the respective section.
2.3
Connection of the drives
This section will introduce the functions of the Version AD CM M1S, which are identical for all versions of the AD
CM M_S.
Please refer to sections 3 and 4 for the installation and set-up of the additional functions offered by the versions
AD CM M2S and AD CM M3S.
Command
LED « busy »
Switch
Power supply
+ Motor
Motor A
Current selection