Specifications subject to change without notice
Description of function of inputs and outputs
8.2. Outputs
8.2.1. Current monitor Monitor I (19)
a current monitor for supervisional purposes is integrated to the servo amplifier.
The output provides an analog signal (voltage) which is proportional to the motor current.
the monitor output is short circuit proof.
Output range:
-10 V... +10 V
Output impedance:
10 k
Ω
Output proportionality: 0,5V/A
Output circuit current monitor:
8.2.2. Speed monitor Monitor n (20)
a speed monitor for supervisional purposes is integrated to the servo amplifier.
The output provides an analog signal (voltage) which is proportional to the motor speed.
It can be used for qualitative weighting of the dynamic of the drive system.
Output range:
-10 V... +10 V
Output impedance:
10 k
Ω
Output proportionality: 10V at maximum speed
Output circuit speed monitor:
MONITOR N
10K
11
MONITOR L
10K