14
Technical Data
7
Operating Data
7.1
6501.00088
Power supply for electronics
U
elo
3,5 … 30
V
Power supply for motor
U
mot
0 … 30
V
Current consumption of electronics
I
el
0.1
A
Temperature range:
– Operating temperature
0 … +65
°C
Dimensions and weight:
– Dimensions (L × W × H)
80 × 65 × 31
mm
– Weight
45
g
Connection information
7.2
Connector / Control
X1
Terminals for power supplies
Pin 1:
GND
Ground connection of power supply / supplies
Pin 2:
U
elo
Power supply for electronics
Pin 3:
U
mot
Power supply for motor winding
X2, X3, X6, X10
Terminals for motor / motor controller
Pin 1:
U
P
Power supply for motor electronics
Pin 2:
U
mot
Power supply for motor winding
Pin 3:
GND
Power supply negative pole
Pin 4:
U
nsoll
Output for nominal speed setting 0 ... 10 V
Pin 5:
DIR
Output for direction of rotation setting
Pin 6:
FG
Input for speed signal from motor controller
X5
RS232 connector, may optionally be used instead of X9 in PROG mode for programming.
X9
USB connector, may optionally be used instead of X5 in PROG mode for programming.
JP1
Jumper can be removed and connected to an amperemeter for motor current measurement at U
mot
.
JP3
1–2:
U
P
= U
mot
Joint power supply to electronics and motor winding via terminal U
mot
.
2–3:
U
P
= U
elo
Power supply to electronics via separate terminal U
elo
(separate power supply for electronics and motor
winding). Power supply for adapter board also via the terminal selected for U
P
.
JP9
Connector for external signal for U
nsoll
, e. g. PWM signal for speed setting. Note: JP10 must then be removed.
JP10
Jumper for selection of the source for U
nsoll
. Closed: U
nsoll
adjustable with P1.
S1
Switch for setting the operating mode.
“PROG “mode
software update
“MOT” mode
motor operation
S2
Switch for setting the direction of rotation of the motor.
S3
Switch for switching the power supply UP for the electronics on / off.
P1
P1 is used to set U
nsoll
from 0 ... 10 V. JP10 must be closed. The power supply U
P
must be at least 10,5 V.
LED1
Indicates the adapter board is ready for operation.
LED2
Indicates the external controller status of output FG.