Step 9:
Install the AFGUARD® in the socket with one of the provided special KLINGERSIL-sealings. Start with
the 2 mm one and check the AFGUARD orientation in the pipe section. If not adequate
–
replace it
with the 1.5mm one.
Use the special AFGUARD® torque spanner to achieve the recommended torque of 50Nm.
Step 10: AFGUARD spanner - FAUDI article no 600513
Connect the AFGUARD® to the control system of the truck / tank farm by using the blue two wire
cable.
For hazardous area use, please ensure to only use the AFGUARD® together with a suitable barrier
with power supply.