4. Unpacking the Unit 

 

 

FATEK HMI x1 

 

Hook and Screw x7

 

 

FATEK PLC 

Connector Rubber 

Cover x1

 

 

A4 Double-sided Installation Guide x1 

 

Power Connector x1

 

 

Pluggable Terminal 

Block x1 

 

5. Installation 

Procedures 

 

 

 

 

 

z

  Push the HMI into the cutout until the 

waterproof ring contacts the plate. 

 

z

 

Insert a hook

 

into each mounting hole

 

on the HMI, and then tighten the 

screws evenly

 

with a moderate torque.

 

z

 

Failure to tighten the screws may 

cause the HMI to fall, malfunction

 

or 

short-circuit. Excessive tightening may 

cause deformation.

 

The necessary 

torque

 

is

 

about 0.16N

·

m.

 

 

5

Содержание P5102S

Страница 1: ...damaged avoid contact with the leaked liquid crystal If the liquid crystal spills on clothing or skin use soap and wash off thoroughly In case of eye contact the liquid hold the eye open flush with plenty water and get medical attention as soon as possible z Do not touch any terminals while the power is on Otherwise it may cause injury due to electrical shock z Disconnect the power supply before i...

Страница 2: ... contact our sales department z Do not use the output signal of the device as any safety function or system emergency stop It may result in personal injury or equipment damage if a malfunction of the touch occurs 1 4 Maintenance and Service z The agreed guarantee applies z Only qualified personnel should make repairs and perform maintenance z Disconnect the device from the power supply before carr...

Страница 3: ...Switch HB1 PLC Screw Hole Power Connector COM3 COM4 Pluggable Terminal Block Ethernet RJ45 Connector for N N1 model Mini USB Connector USB Connector COM1 DB 9 Male Connector Micro SD Card Slot for N1 model Audio Phone Jack for N1 model W 271 5 mm H 213 5 mm D 44 6 mm 1 2 3 4 5 6 7 8 9 10 11 12 13 W H D 3 ...

Страница 4: ...ment type Permanently connected Fixed I O Port Serial 1 Connector D Sub 9 Pin COM1 RS 232 TXD RXD RTS CTS Serial 2 Connector Pluggable Terminal Block COM3 RS 422 485 Isolation COM4 RS 485 Isolation LAN 10M 100M 10M 100M USB USB2 0 Type A Host x1 USB2 0 Type mini B Device x1 Micro SD Yes Audio Yes PLC Extension HB1 main units B1 extension modules Termination Switch Yes For RS 422 485 Power Power In...

Страница 5: ...nstallation Procedures z Push the HMI into the cutout until the waterproof ring contacts the plate z Insert a hook into each mounting hole on the HMI and then tighten the screws evenly with a moderate torque z Failure to tighten the screws may cause the HMI to fall malfunction or short circuit Excessive tightening may cause deformation The necessary torque is about 0 16N m 5 ...

Страница 6: ...on resistor switch To enable or disable the termination resistor please follow the configuration shown in the table below The termination switch is for COM3 RS 422 RS 485 and COM4 RS 485 z Configuration of Termination Resistor Switch Termination Resistor No COM3 RS 422 COM3 RS 485 COM4 RS 485 Enable Disable Enable Disable Enable Disable 1 ON OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF 3 ON OFF ON...

Страница 7: ...S 232 1 NC 1 2 RX 3 TX 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC 1 NC No Connection Pluggable Terminal Block PIN COM3 RS 422 COM3 RS 485 COM4 RS 485 1 NC NC DATA 2 NC NC DATA 3 ISO_GND ISO_GND ISO_GND 4 RX NC NC 5 RX NC NC 6 TX DATA NC 7 TX DATA NC 1 2 3 4 5 6 7 7 ...

Страница 8: ...and saving space using FATEK HB1 main units B1 extension modules is recommended z The rubber cover of the PLC connector can be taken off and placed into the termination switch slot 8 R Pobrano z https panele hmi pl panel hmi 10 2 p5102s fatek ...

Отзывы: