Operation Guidelines

CAUTION

Exceeding the generator's wattage/amperage capacity may damage
the generator and electrical devices connected to it.

Do not connect any electrical loads before starting the engine and 
allowing it to warm up. Make sure electrical devices are "off" when 
you do connect them.

Starting the Engine

1. Place the generator on a level surface.

2. Turn the fuel valve to the "on" position.

3. Move the choke lever to the "closed" position.

4. Pull slowly on the starter cord until it engages, then pull sharply.

CAUTION

Do not allow the starter cord to snap back. Return it slowly by hand.

5. Move the choke lever back to the "open" position after the engine

warms up.

High-Altitude Operation

The standard carburetor air-fuel mixture will be too rich at high altitude
(5,000 feet or 1,500 m and above), decreasing performance and increasing
fuel consumption. 

Electrical Loads

Before connecting an appliance or power cord to the generator, 
make sure the appliance or cord is in good working order. Do not 
overload the generator! The GT950's specifications are:

To make sure that your generator can supply enough rated (running) 
and surge (starting) watts for the items you will power at the same time,
follow these steps:

1. Select the items you will power at the same time.

2. Add up the rated (running) watts of these items. The generator must

produce this total amount of power to keep your items running.

3. Estimate how many surge (starting) watts you will need; in other words,

the short burst of power needed to start electric tools or appliances.
Because not all motors start at the same time, total surge watts can 
be estimated by adding only the item with the highest additional surge
watts to the total rated watts.

Example of determining the total output required:

Tool/Appliance

Rated (Running) Watts

Surge (Starting) Watts

Refrigerator

800

1,600

Television

500

n/a

Window AC

1,200

1,800

Total Rated (Running) Watts = 2,500

Highest Surge Watts = 1,800

Total Generator Output Required = 4,300

ON

ON

ON

FUEL VALVE LEVER

OFF

OFF

OFF

O

FF

ON

AC

PROTECTOR

~

RESET
OFF

ON

ENG - SW

1

0

STOP

CHOKE LEVER

CHOKE LEVER

CHOKE LEVER

OPEN

OPEN

OPEN

CLOSED

CLOSED

CLOSED

O

FF

ON

STARTER GRIP

STARTER GRIP

STARTER GRIP

Rated Voltage (V)

120

Rated Frequency (Hz)

60

Rated Current (A)

7.3

Rated Output (VA)

800

Содержание GT950

Страница 1: ... for Aquatic Eco Systems Inc Phone 407 886 3939 Fax 407 886 6787 aes aquaticeco com aquaticeco com Commercial Duty Power Systems User s Guide Model No GT950 AC PROTECTOR RESET OFF AC OUT ON ENG SW 1 0 STOP Serial Number Date Purchased ...

Страница 2: ...n Guidelines 5 Starting the Engine 5 High Altitude Operation 5 Electrical Loads 5 Wattage Reference Chart 6 Stopping the Engine 6 Transport 6 Periodic Maintenance 6 Spark Plug Inspection 6 Air Filter Cleaning 7 Fuel Sediment Cup Cleaning 7 Fuel Tank Filter Cleaning 7 Maintenance Chart 8 Miscellaneous 8 Troubleshooting 9 Generator Won t Start 9 No AC Output 9 Generator Falters Under Load 9 Generato...

Страница 3: ...vided in this manual before operating your generator Operator Responsibility Know how to stop the generator quickly in case of an emergency Understand the use of all generator controls output receptacles and connections Ensure that anyone who operates the generator has proper instruction Do not let children operate the generator Carbon Monoxide Hazard Exhaust contains poisonous carbon monoxide a c...

Страница 4: ...oil mix Refill the tank outdoors Remove the gas cap slowly to relieve any pressure inside the tank Keep sparks flames heat and other ignition sources away while adding or storing oil and fuel Do not light a cigarette or smoke when refueling Wipe up any fuel spills WARNING Improper connections to a building s electrical system can allow electrical current from the generator to backfeed into utility...

Страница 5: ...r cord is in good working order Do not overload the generator The GT950 s specifications are To make sure that your generator can supply enough rated running and surge starting watts for the items you will power at the same time follow these steps 1 Select the items you will power at the same time 2 Add up the rated running watts of these items The generator must produce this total amount of power...

Страница 6: ...ch and fuel lever are in the off positions Keep the generator level to prevent fuel spillage Fuel vapor or spillage may ignite WARNING Contact with a hot engine or exhaust system can cause serious burns or fires Let the engine cool before transporting the generator Take care not to drop or strike the generator while transporting Do not place heavy objects on the generator Never operate a damaged o...

Страница 7: ...er element and gently squeeze out excess oil Never wring out the filter element as it may tear The generator will smoke if too much oil remains in the filter element 4 Reinstall the filter element and air filter cover Be sure both projections of the air filter cover fit the control box slots before tightening the mount screws Fuel Sediment Cup Cleaning 1 Remove the cup at the bottom of the fuel va...

Страница 8: ...Months 50 hrs Six Months 100 hrs Twelve Months 300 hrs Spark Plug Check condition Adjust gap and clean Replace if necessary X Air Filter Clean replace if necessary X Fuel Filter Clean fuel valve and fuel tank filter Replace if necessary X Fuel Line Check fuel hose for cracks or other damage Replace if necessary X Exhaust System Check for leakage Retighten or replace gasket if necessary X Check muf...

Страница 9: ...ctrical Loads on page 5 2 A connected device has a short circuit Disconnect the shorted load 3 The generator has a short circuit Contact AES Generator Shuts Down While Running 1 Check the fuel oil mix level and add more if necessary Storage Your generator should be started at least once every seven days and allowed to run at least 30 minutes If you must store the generator for longer periods of ti...

Страница 10: ...r charges or other incidental or consequential damages with respect to persons animals business or property whether as a result of breach of warranty negligence or otherwise Notwithstanding any other provision of this warranty BUYER S REMEDY AGAINST AES FOR GOODS SUPPLIED OR FOR NONDELIVERED GOODS OR FAILURE TO FURNISH GOODS WHETHER OR NOT BASED ON NEGLIGENCE STRICT LIABILITY OR BREACH OF EXPRESS ...

Отзывы: