Fastus UR-DS4AD Скачать руководство пользователя страница 28

28 

Na

m

Ind

ex nu

m

be

S

ubi

nd

ex

 

 

R

ea

d/

W

rit

e*

B

ac

kup

 S

ubj

ec

Dat

a b

yt

e c

ou

nt

 

De

fau

lt v

al

ue

 

Se

tu

p v

al

ue

 

S

et

tin

g D

et

ail

Averaging time 

79 

R/W 

 

 

Sets the averaging time for channels 0 to 3. 

1 to 4

 

 

750 

µ

1.5 ms 

3 ms 

6 ms 

12 ms 

24 ms 

48 ms 

Internal 
temperature 

161 

 

-2739 to 

10461 

Returns the temperature on the internal board. The unit is 0.1

°

C. 

Operating time 

162 

 

 

0 to 

4294967295

 

Returns the internal operation time. The unit is 7.5 minutes. 

Displayed 
decimal point 
position 

193 

R/W 

 

 

Specifies the decimal point position for the process input data 
displayed on the IO-Link master UR series. The first byte 
corresponds to channel 0. 

1 to 4

 

 

0 to10 

Each channel is set separately. Subindex number 1 corresponds 
to channel 0. 

Display unit 
character string 

194 

1 to 4

  R/W 

 

None

 

Specifies the unit character string for the process input data 
displayed on the IO-Link master UR series. 

Device 
identification 
request   
(Find me) 

204 

R/W 

 

Normal status 

Flash the COM LED at 0.55 second intervals 

 

 

 

Ramco Innovations                 www.optex-ramco.com                     (800) 280-6933

Содержание UR-DS4AD

Страница 1: ...OPTEX FA IO Link Hub UR DS4AD UR DS4DA User s Manual OPTEX FA CO LTD For technical support and application assistance contact the Optex IO Link experts at Ramco Innovations today Ramco Innovations ww...

Страница 2: ...before using UR DS4AD UR DS4DA correctly Also keep this manual in a safe place after reading it and always keep it handy Trademarks and registered trademarks that appear in this manual are the propert...

Страница 3: ...communication terminals on the power terminal block 11 Wiring to the analog input output power supply 12 Wiring to the device terminal block for UR DS4AD 12 Wiring to the device terminal block for UR...

Страница 4: ...s for UR DS4AD 21 9 Circuit Diagram 22 Analog input circuit diagram for UR DS4AD 22 Analog output circuit diagram for UR DS4DA 22 10 Process Data 23 UR DS4AD 23 Word assignment 24 UR DS4DA 25 Word ass...

Страница 5: ...5 Ramco Innovations www optex ramco com 800 280 6933...

Страница 6: ...speci es 4 analog output signals to control various actuators with process output data from the IO Link master It can be used to control devices with analog input such as changing the speed of a motor...

Страница 7: ...7 3 Dimensions UR DS4AD UR DS4DA 39 9 21 5 Unit mm 85 63 85 63 21 5 39 9 Unit mm Ramco Innovations www optex ramco com 800 280 6933...

Страница 8: ...e DIN rail 2 Push the lower side from the front 3 Push the DIN rail mounting hook up to lock the product in place This illustration is for UR DS4AD Install UR DS4AD UR DS4DA at least 10 mm away from a...

Страница 9: ...9 5 System Con guration Ramco Innovations www optex ramco com 800 280 6933...

Страница 10: ...V and C Q are connected internally with the terminals of the e CON socket Power supply for analog output devices Connecting to the IO Link communication e CON socket See page 11 Connecting to the IO...

Страница 11: ...tween AWG 28 to 20 stranded wires with a rated temperature of 75 C or higher Connecting to the IO Link communication terminals on the power terminal block Connect the 0V C Q 24 V terminals on the powe...

Страница 12: ...used and recommended ferrule refer to Wire Installation on page 13 Wiring to the device terminal block for UR DS4AD Connect the wires for power supply and input signal of input devices to the 16 chan...

Страница 13: ...ength of single or stranded wire should be 10 mm Wire to be used Use wires with a diameter compatible with the terminal blocks Power terminal block 24V 0V L M C Q AWG24 to 12 Use wires with a temperat...

Страница 14: ...maged when pulling it out Unit mm Terminal block AWG Ferrules from PHOENIX CONTACT Model Dimensions Insulation sleeve color L1 L2 D1 S1 D2 S2 Device terminal block 24 AI 0 25 8 YE 12 50 8 00 0 80 0 15...

Страница 15: ...e pressing the open close key Insert the wire until the tip reaches the bottom 3 Release the open close key to complete wiring Pull gently to make sure it does not come loose Power terminal block For...

Страница 16: ...e ferrule is stuck inside the terminal block and cannot be removed the terminal block may be damaged by forceful removal If the ferrule is stuck move the ferrule up down left or right while pressing i...

Страница 17: ...nd the shield wire SLD to the analog output device 6 Device terminal block L M Used to supply 24 V power L M to the analog output device 7 Power terminal block 0 V 24 V Supplies unit power 24 V 0 V an...

Страница 18: ...V power supply L M to analog input devices 6 Power terminal block 0 V 24 V Supplies unit power 24 V 0 V and output power L M This seven pole removable connector has a pitch of 5 08 mm and a rating of...

Страница 19: ...ive 2014 30 EU Environment RoHS Directive 2011 65 EU China RoHS Regulation 32 Applicable standard EN 61131 2 Zone A Company standards Noise resistance Feilen Level 3 cleared Compatible DIN rail TH35 7...

Страница 20: ...t voltage 11 V Maximum input current 24 mA Voltage input equivalent impedance 250 5 k ohm Current input equivalent impedance 246 ohm Voltage accuracy 0 30 of F S at ambient temperature of 25 C 1 Tempe...

Страница 21: ...typical 8 ppm C 0 0008 C Current accuracy 0 2 of F S at ambient temperature of 25 C Temperature coef cient typical 10 ppm C 0 001 C Input resolution 16 bits Dielectric withstand voltage 500 VAC for o...

Страница 22: ...r UR DS4DA GND I 0 to 3 V 0 to 3 Internal circuit 1 2 3 82 K ohm 82 ohm 168 3 K ohm 164 ohm Voltage sensing Voltage output Current output GND Internal circuit 1 2 3 15 ohm 15 ohm 20 ohm 0 01 F 0 01 F...

Страница 23: ...input lower byte 6 Channel 0 Analog input upper byte 7 Channel 0 Analog input lower byte Process output data 0 2 Channel 3 Input type 0 0 to 10 V 1 10 to 10 V 2 0 to 5 V 3 0 to 20 mA Channel 2 Input t...

Страница 24: ...nel 0 Analog input lower byte N 1 Channel 1 Analog input upper byte Channel 1 Analog input lower byte N 2 Channel 2 Analog input upper byte Channel 2 Analog input lower byte N Channel 3 Analog input u...

Страница 25: ...te n 5 Channel 1 Analog output upper byte n 6 Channel 1 Analog output lower byte n 7 Channel 0 Analog output upper byte n 8 Channel 0 Analog output lower byte 1 If index number 74 output range selecti...

Страница 26: ...annel 2 Analog output lower byte N 3 Channel 3 Analog output upper byte Channel 3 Analog output lower byte N 4 1 N A Channel 3 output type Channel 2 output type Channel 1 output type Channel 0 output...

Страница 27: ...o 0 to 5 V voltage input 4 Sets to 1 to 5 V voltage input 5 Sets to 0 to 20 mA current input 6 Sets to 4 to 20 mA current input Maximum span value 76 0 R W 8 32000 Sets the maximum span value for chan...

Страница 28: ...ion time The unit is 7 5 minutes Displayed decimal point position 193 0 R W 4 0 Speci es the decimal point position for the process input data displayed on the IO Link master UR series The rst byte co...

Страница 29: ...imum span value for channels 0 to 3 Speci es the value given to the process output data when outputting the maximum value of the output range The rst two bytes are the value for channel 0 1 to 4 2 0 t...

Страница 30: ...10 Each channel is set separately Subindex number 1 corresponds to channel 0 Display unit character string 194 1 to 4 R W 6 None Speci es the unit character string for the process input data displayed...

Страница 31: ...ater than Maximum span value The minimum span value setting is greater than the maximum span value The span width works as 32000 This event occurs only at startup x1801 The setting value memory write...

Страница 32: ...ameter M10 I O function setting COM LED is ashing at 0 1 second intervals IO Link communication has broken off Check the wiring between the IO Link Master and C Q Check that the other IO Link communic...

Страница 33: ...process data monitor If the IO Link master is the UR series from OPTEX FA check if the required amount is allocated in M40 Process input data words allocation in the master parameter Check the wiring...

Страница 34: ...3 and the GND terminal so check that the analog input wires of the analog input device are wired correctly Check that the bit corresponding to the output range setting of the process output data of t...

Страница 35: ...d off Noise on the analog output Select a current input device because the impedance of the receiving equipment is lower with a current input than with a voltage input Alternatively connect a 250 for...

Страница 36: ...36 The information in this user s manual is correct as of February 2024 UR DS4_UM E_001_2402 Ramco Innovations www optex ramco com 800 280 6933...