FT600(K)SIP Door Phone Administrator Guide
38
web
Intercom > Relay
interface.
Parameter Set-up:
⚫
Relay ID:
you are allowed to set up three relay switches in total for the door
access control.
⚫
Relay Type:
if the Default state is selected, the Relay Status shows Low
which means the door is closed, the Relay Status shows which means the
door is opened. If Invert State is selected, the Relay Status hows High which
means the door is closed, and Low means the door is opened.
⚫
Relay Mode:
there are two modes Monostable and Bistable. If Monostable
is selected, the relay status will be automatically reset within the relay
delay time after the relay is triggered. If Bistable is selected, relay status
will be reset after the relay is triggered again.
⚫
Relay Delay (Sec):
set the relay trigger timing (Ranging from 1-60 Sec.) For
example, if you set the activation time as “
5
” Sec. Then the relay will give a
pulse for 5 seconds
⚫
DTMF Option:
select the number of DTMF digits for the door access control
(
Ranging from 1-4 digits
). For example, you can select 1 digit DTMF code
or 2-digit DTMF code, etc, according to your need.