background image

New Classic Edition 2.0 

 

 

 

FASTTEL Klipsenstraat 18A  9160 Lokeren 

Tel : + 32 (0) 9 244 65 20    FAX:+ 32 (0)  9 244 65 29  Email: 

[email protected]

 

                                       

Web  : 

WWW.FASTTEL.BE

   

 

15

Code 

2 12

 letter 

#

 

2 13

 letter 

2 14

 letter 

2 15 

letter 

C

 

Code 

2 16

 letter 

D

 

 

Attention !

 

If the “end of conversation” code is the same as the code for operating the (door) contact, dan the 
door contact will automatically be first operated, and then the connection will be ended. 
 

Extra function 
 

The wizard classic has thus 1 relay on board. The user can activate this relay by pushing the 2 on his 
telephone keypad. If the user desires more than 1 relay or/and he wishes not to have the relay at the 
outside in the door phone the FT4SW or FT8SW offers the solution. These modules offer 4 and 8 
extra relays safely in the house. Normally these relays are activated via the telephone keypad 
forming the codes #001 for raly 1 up to #008 for relay 8. 
But you can chose anyway to activate 1 relay of the FT4SW or FT8SW by forming the short code 2. 
 
Code 2: use code 936ab where  a= address FT4SW or FT8SW (if a=* the internal relay of the door 
phone will be activated (default)) 
 

 

 

 

b= relay 

 
attention: to be able to connect the FT4SW or FT8SW the plug in board FT29LON must be ordered.  
 

12. Setting max. conversation time 

 
This setting sets the maximum conversation time. After this time the Wizard will end the 
conversation automatically. 
This conversation time can be set in steps of 5 seconds and can be multiplied by 01 to 99. 
 

How ?

 

Code 

80 xx

 

value to be set 

Code 

80 00

 

maximum conversation time (60 minutes) 

Code 

80 24

 

conversation time 24 x 5 seconds= 2 minutes  (default) 

Code 

80 50 

conversation time 50 x 5 seconds = 250 seconds or 4 minutes, 10 seconds. 

 

13. Setting push time button  

 
This setting allows you to settle the push time needed before the call will be made.

 

Remark: only for the models without key board. 
 

How? 

 
Code 

931AB 

where AB stands for the number of steps of 0,1 seconds. 

 
e.g 

93101 = 100 msec (=default) 

 

93110 = 1 second

 

 

 

14. Setting toggle/impulse contact

 

 

With this setting, you can choose between toggle (on/off) contact or impulse contact.

 

 

New Classic Edition 2.0 

 

 

 

FASTTEL Klipsenstraat 18A  9160 Lokeren 

Tel : + 32 (0) 9 244 65 20    FAX:+ 32 (0)  9 244 65 29  Email: 

[email protected]

 

                                       

Web  : 

WWW.FASTTEL.BE

   

 

16

This setting is useful if you use the contact for operating the doorlock. 
You can choose toggle if you want to operate an on/off switch 
 

How ?

 

Code 

6 10

 

Impulse contact (door lock) 

Code 

6 11

 

Toggle contact 

 

15. Setting time (door) contact 

 

This setting sets the time of the (door) contact.

 

 
When using the door contact, it is advised to activate the lock +/- one second. 
Or you can operate a light and set a timer in 5 second steps. 
These steps can be set from 01 to 99. 
 

How ?

 

Code 

81 00

 

contact not active 

Code 

81 01

 

time duration one step (5 seconds or 100 msec.) consult setting contact 

steps 
Code 

81 99

 

time duration 99 steps 

 
eg. 

Steps 5 seconds 

8112 = 12 x 5 seconds = 60 seconds 

eg. 

Steps 100 msec. 

8112 = 12 x 100 mseconds . 1200 msec. 

 

16. Setting contact steps 5 sec./100 msec.

 

 

You can set the contact in steps of either 5 seconds or 100 msec.

 

 
When using the doorlock it is advised that you set the contact in steps of 100 msec. 
You can then set the code 81 xx to 10 (1 second). 
If you choose to switch on a light, you can choose the 5 seconds steps. 
You can then use the contact as a timer contact. 
 

How ?

 

Code 

5 20

 

contact in steps of 5 seconds max. = 99 x 5 sec. = 8 min. 15 sec. 

Code 

5 21

 

contact in steps of 100 msec. max. = 99 x 100 msec. = 9.9 sec. 

 

17. Setting loudspeaker level and micro sensitivity

 

 

This setting allows you to adjust the loudspeaker level and micro sensitivity to a default 
level at the installation of the Wizard.

 

 

How ?

 

The installer sets the level via : code 

88

 XX 

XX =value between 00 and 15. 
 

Содержание DB9701

Страница 1: ...s control key pad Wizard 2 push buttons access control key pad Wizard 3 push buttons access control key pad Wizard SAS for flexible built in applications All these models can be equipped with or without camera Options Datalink I O module FT4SW or FT8SW with plug in FTLON PC programmable module Speech module 2 x 8 seconds T V Twisted pair video UHF module LCD built in video monitor LCD desktop mode...

Страница 2: ...32 0 9 244 65 20 FAX 32 0 9 244 65 29 Email info fasttel be Web WWW FASTTEL BE 4 User instructions 1 Communicate with doorphone There are two possibilities to communicate with the door phone When a visitor rings at the door The telephone will ring at the programmed number extension or telephone number When you answer you will hear DTMF tones or speech option as a sign that the call is coming from ...

Страница 3: ... switch the microphone of the door station on or off New Classic Edition 2 0 FASTTEL Klipsenstraat 18A 9160 Lokeren Tel 32 0 9 244 65 20 FAX 32 0 9 244 65 29 Email info fasttel be Web WWW FASTTEL BE 6 In very noisy situations eg Petrol stations it can be necessary to temporarely switch the microphone of the door station on or off How During the conversation you enter the correct code Code 3 mute o...

Страница 4: ...E 8 INSTALLER MANUAL 1 Connections Opening surface mounted model 1 On top and below you see two gradual plates 2 These are fixed with each 2 screws 3 You unscrew these two screws with the enclosed tool 4 Remove the two plates which are now loose 5 You now see 4 screws 6 Unscrew the 4 screws on top and below 7 You can now clipse the front plate loose by pulling softly Opening of flush mounted model...

Страница 5: ...alling let ring at least one time and not more the 3 times You put the phone down and call back within 20 seconds New Classic Edition 2 0 FASTTEL Klipsenstraat 18A 9160 Lokeren Tel 32 0 9 244 65 20 FAX 32 0 9 244 65 29 Email info fasttel be Web WWW FASTTEL BE 10 4 Programmation codes Wizard In the table below you find all the programmation codes to personalize the behavior of the Wizard only after...

Страница 6: ...ew Classic Edition 2 0 FASTTEL Klipsenstraat 18A 9160 Lokeren Tel 32 0 9 244 65 20 FAX 32 0 9 244 65 29 Email info fasttel be Web WWW FASTTEL BE 12 Code 82XX with XX the number of rings before dialing next destination default 8210 appr 10 rings When a dialed number is occupied this number can be repeated several times You can choose to switch this function on or off How Code 6 60 no redial when oc...

Страница 7: ...ASTTEL BE 14 The changeover can also proceed automatically using the optional data module FT4SW of FT8SW An external relay provides this module with a closed contact which in turn will switch the Wizard in daytime operation or nighttime operation This can for instance be done by means of a timer or when an alarm is activated Just like the case can be when setting the device manually you can also c...

Страница 8: ...he push time needed before the call will be made Remark only for the models without key board How Code 931AB where AB stands for the number of steps of 0 1 seconds e g 93101 100 msec default 93110 1 second 14 Setting toggle impulse contact With this setting you can choose between toggle on off contact or impulse contact New Classic Edition 2 0 FASTTEL Klipsenstraat 18A 9160 Lokeren Tel 32 0 9 244 ...

Страница 9: ... 32 0 9 244 65 20 FAX 32 0 9 244 65 29 Email info fasttel be Web WWW FASTTEL BE 18 21 Setting activation door contact on call When a visitor pushes the button on your Wizard doorstation the door contact is automatically activated This is very much used in medical practices The entering of the person in you building is announced by the ringing of your telephone How code 510 do not activate door con...

Страница 10: ...y the video image of this visitor is shown on your PC when activated This kit contains a VOTP system PC videocard and the software 27 Setting use password Use of PIN code to activate door contact How Code 5 50 no password Code 5 51 password active After you have entered the standard door contact activation code you will hear 3 tones This means the Wizard waits for you to enter your PIN code which ...