Flow Rate Head Loss and Pump Sizing
Fig No.13
The WH and WHX units will operate within a water inlet pressure
range from 1.0 bar to 10.0 bar.
When a pump is used with a storagae system or for secondary
return circulation only bronze or stainless steel pumps must be used.
The pump must be sized to give a minimum flow rate of 8 L/min
through each heater.
The head loss through the FASTflo range of products is due to the
friction generated when the water flows through the heat exchanger
and associated components.
Water Flow (litres/minute)
Head
L
oss
(bar)
0
2.5
2
1.5
1
0.5
0
5
10
15
20
25
30
A suitable 3 speed bronze pump kit with ball valve unions to 28mm cu. can
be supplied by Andrews, part no.B249 (see Fig No. 14)
Pump Selection using multiple heaters (pump required for first unit only)
Number of units
Flow rate required
Approximate head
Speed setting
1
8 l/min - 0.13 l/sec
50 kPa
2
Pump selection using multiple heaters (flow through all units)
2
16 l/min - 0.27 l/sec
50 kPa
2
3
24 l/min - 0.40 l/sec
60 kPa
3
4
32 l/min - 0.53 l/sec
60 kPa
3
5
48 l/min - 0.67 l/sec
60 kPa
3
6
48 l/min - 0.80 l/sec
60 kPa
3
Содержание LWH56
Страница 18: ...Dimensions WH42 LWH42 WH56 and LWH56 Fig No 15...
Страница 19: ...Dimensions WHX56 and LWHX56 Fig No 16...
Страница 20: ...WH42 LWH42 WH56 and LWH56 Pre assembled dual manifold unit dimensions Fig No 17...
Страница 21: ...WH42 LWH42 WH56 and LWH56 Pre assembled triple manifold unit dimensions Fig No 18...
Страница 22: ...WHX56 and LWHX56 Pre assembled dual manifold unit dimensions Fig No 19 Note Pipework covers are optional...
Страница 23: ...WHX56 and LWHX56 Pre assembled triple manifold unit dimensions Fig No 20 Note Pipework covers are optional...