background image

                                                     “EGA Spółka z o.o.” Spółka Komandytowa ul. Rzeczna 1, Nowa Wieś Rzeczna   
                                                          83-200 Starogard Gdański tel/fax:+48 58 56 300 80 

www.ega.com.pl

 

- Place the jack on a level surface and open the drain valve. The correct oil level is at the bottom of the 
thread inside the oil chamber when the lifting arm is in the fully lowered position. In the absence of oil, 
remove the vent cap located under the cap. Fill the oil to the correct level, fit and tighten the plug. 

- Close the drain valve and raise the lifting arm to its full upper position. Then, open the drain valve 
and on the support force to lower the lift as quickly as possible. 

- Repeat this operation three or four times. This procedure thoroughly rinses the valves and ensures 
complete distribution of the oil. In most cases, restore this to work. Firmly close the drain valve and 
test the lift under load. 

b) There may be air in the lift system. Then open the drain valve and make a handle of six full 
movements. Then close the drain valve and try again the jack. 

c) The pump sealing ring may be worn. This situation can only occur after many months of use. A new 
sealing ring or new piston can be purchased and installed without problems. 

D) The drain valve may remain open under the influence of dirt on the seal. Rinse the valve and 
gasket, lifting and lowering the levers several times with the valve open. If necessary, you can take a 
photo of the valve to clean the valve itself and the valve seat. 

2. If the lift is lowered under load: 

a) The bleed valve can be held in the ball socket. In the case of a dirty drain valve or ball socket, the 
lift can quickly lower, causing the handle to move up and down quickly. 

This is due to the rapid oil flow back into the pump chamber through the open ball socket. 

In this case, it is recommended to carry out the procedure 1-a before commencing the partial 
dismantling of the hydraulic unit. 

The bleed valve is located at the bottom of the spindle cylinder. In addition, there is also a washer with 
a screen. Carefully remove it and replace it with a new one if damaged. 

Then, remove the drain valve ball and thoroughly clean the valve seat. Wipe the ball and put it in 
place. Use a 1/4 "and 3" gauge and a small hammer.  In this way, put the ball back in the slot. Install 
the washer with the sieve, firmly tighten the stem cylinder. 

Replace the washers at the top and bottom of the oil chamber, install the stem assembly and screw 
the top of the unit. 

b) The gasket of the stem may be worn. This may occur in case of heavily operated lifts. Follow the 
above 2-a procedure to gain access to the stem assembly. Remove the worn gasket by pulling it out or 
cutting a small knife. Be careful not to damage the new seal during installation. 

c) Dirt in the drain valve reduces the lift under load. Remove the drain valve, clean its seat and 
reinstall the valve. 

3. If the lift does not lower completely after lifting: 

a) The return spring of the lifting arm may be cracked or detached. Replace the return spring. 

b) Lubrication is probably required. Clean and lubricate all moving parts in the lifting arm mechanism. 

c) The hydraulic unit may contain too much oil and the vent valves may be closed. Open the vent plug. 

4. Lift does not lift full 2,5 ton load: 

a) The sealing ring of the pump piston may be worn. See instructions III 1-c. 

b) There may be air in the unit. See instructions III 1-b. 

c) The relief valve is factory-set to lift a load of 2 tons and its setting should not be changed. Check the 
lifting harness, which may cause a load loss. 

Содержание 358-2T

Страница 1: ...el fax 48 58 56 300 80 www ega com pl PODNO NIK S UPKOWY HYDRAULIC BOTTLE JACK Nr kat 358 2T 359 3T 360 5T 361 10T Oryginalna Instrukcja Obs ugi Instruction Manual EGA SP KA Z O O SP KA KOMANDYTOWA UL...

Страница 2: ...i obracaj w prawo a zaw r spustowy zostanie zamkni ty Podno nik jest gotowy do pracy 2 W rami podnoszenie do gniazda i stale podnosz c i opuszczaj c spowodujesz podnoszenie podpory podno nika do mome...

Страница 3: ...o podno nik mo e szybko si obni a powoduj c szybki ruch uchwytu w g r i w d Jest to spowodowane szybkim przep ywem oleju z powrotem do komory pompy przez otwarte gniazdo kulkowe W taki przypadku zalec...

Страница 4: ...ylko kraj w Unii Europejskiej W razie potrzeby pozbycia si niniejszego produktu prosimy skontaktowa si z lokalnymi w adzami lub ze sprzedawc celem uzyskania informacji o prawid owym sposobie post powa...

Страница 5: ...361 SERIAL NR NAPRAWY GWARANCYJNE DATA ZG OSZENIA ZAKRES NAPRAWY DATA NAPRAWY DATA ZG OSZENIA ZAKRES NAPRAWY DATA NAPRAWY PIECZ TKA I PODPIS PIECZ TKA I PODPIS DATA ZG OSZENIA ZAKRES NAPRAWY DATA NAPR...

Страница 6: ...a si do przes anego pisma Naprawa towaru zostaje wyd u ona o czas dostarczenia wszystkich dokument w do serwisu 12 W sytuacji gdy klient nie posiada wszystkich dokument w powinien poinformowa serwis o...

Страница 7: ...the supplied pin 2 The lift exits the factory with the vent cap closed at the top of the oil chamber to prevent spillage of oil The oil chamber contains the right amount of oil Before using the cap fo...

Страница 8: ...ly This is due to the rapid oil flow back into the pump chamber through the open ball socket In this case it is recommended to carry out the procedure 1 a before commencing the partial dismantling of...

Страница 9: ...ack stands then carefully remove jack stands always used in pairs 2 Slowly turn the handle anti clockwise but no more than a 1 2 full turn 3 After removing jack from under the load push saddle down to...

Страница 10: ...EGA Sp ka z o o Sp ka Komandytowa ul Rzeczna 1 Nowa Wie Rzeczna 83 200 Starogard Gda ski tel fax 48 58 56 300 80 www ega com pl...

Отзывы: