Fastech Ezi-Step Mini Скачать руководство пользователя страница 12

www.fastech-motions.com - 12

Switch Position

STOP Current (%)

Switch Position

STOP Current (%)

4

3

2

1

4

3

2

1

ON

ON

ON

ON

10

OFF

ON

ON

ON

90

ON

ON

ON

OFF

20

OFF

ON

ON

OFF

100

ON

ON

OFF

ON

30

OFF

ON

OFF

ON

10

ON

ON

OFF

OFF

40

OFF

ON

OFF

OFF

10

ON

OFF

ON

ON

50

*1

OFF

OFF

ON

ON

10

ON

OFF

ON

OFF

60

OFF

OFF

ON

OFF

10

ON

OFF

OFF

ON

70

OFF

OFF

OFF

ON

10

ON

OFF

OFF

OFF

80

OFF

OFF

OFF

OFF

10

12.2 Stop Current Setting Switch(SW1.1~1.4)

Stop Current means the motor current value automatically set in 0.1 sec after motor stops. This is to prevent
the overheat of a motor when the motor is under long time idling. The unit of the selection value is a percentage.

*1 : Default : 50%

12.1 Drive Status LED

Indication Color

Function

ON/OFF Condition

PWR

Green Power Input Indication

Lights when power is ON Flashes when motor is 
Free status

ALM

Red

Alarm Indication

Flash when protection function is activated 
(Identifiable which protection mode is activated 
by counting the flash times)

CW

Yellow Motor Rotation Direction

Lights when motor rotate CW direction

CCW

Orange Motor Rotation Direction

Lights when motor rotate CCW direction

◆ Protection functions and LED flash times

Times

Protection

Conditions

1

Over Current Error

The current through power devices in drive exceeds the 
limit value

*1

2

Over Speed Error

Motor speed exceeded 3,000 [rpm]

3

Step Out Error

Abnormally motor do not followed pulsed input

5

Over Temperature Error

Internal temperature of a motor drive exceeded 85℃

6

Over Regenerative 
Voltage Error

Back EMF more than 50V

7

Motor Connect Error

Power is ON without connection of motor cable to drive

9

Motor Voltage Error

Motor voltage is below 20V

11

System Error

Error occurs in drive system

12

ROM Error

Error occurs in Parameter storage Device(ROM)

*1 : Limit value depends on motor model

Alarm LED flash 

(Ex, Step Out Error)

2.0s

0.5s

12.3 Resolution Setting Switch(SW1.5~1.8)

*1 : Default: 10,000

The Number of pulse per revolution.

Switch Position

Pulse/

Revolution

Switch Position

Pulse/

Revolution

8

7

6

5

8

7

6

5

ON

ON

ON

ON

500

OFF

ON

ON

ON

6,400

ON

ON

ON

OFF

1,000

OFF

ON

ON

OFF

8,000

ON

ON

OFF

ON

1,600

OFF

ON

OFF

ON

10,000

*1

ON

ON

OFF

OFF

2,000

OFF

ON

OFF

OFF

20,000

ON

OFF

ON

ON

3,200

OFF

OFF

ON

ON

25,000

ON

OFF

ON

OFF

3,600

OFF

OFF

ON

OFF

36,000

ON

OFF

OFF

ON

4,000

OFF

OFF

OFF

ON

40,000

ON

OFF

OFF

OFF

5,000

OFF

OFF

OFF

OFF

50,000

Содержание Ezi-Step Mini

Страница 1: ...Operating Manual www fastech motions com...

Страница 2: ...Characteristics of Motor 10 Dimensions of Motor mm 11 Notes on Installation 12 Settings and Operation 12 1 Drive Status LED 12 2 Stop Current Setting Switch SW1 1 1 4 12 3 Resolution Setting Switch SW...

Страница 3: ...e manual is damaged or lost please contact with Fastech s agents or our company at the address on the last page of the manual Our company is not responsible for a product breakdown due to user s disma...

Страница 4: ...Otherwise a fire or other kinds of accidents may occur due to overheating The process of Installation Connection Operation Checking and Repairing should be done with qualified person Otherwise a fire...

Страница 5: ...Ezi STEP MINI The machine may get damaged or the user may get injured by motor operation All parameter values are set by default factory setting value Change this value after reading this manual thro...

Страница 6: ...g in high precision Microstep operation High precision Microstep function and Filtering 2 Software Damping Vibration suppression and High speed operation Patent pending Motor vibration is created by m...

Страница 7: ...42S EzStep MI 42S Ezi STEP MI 42M BM 42M EzStep MI 42M Ezi STEP MI 42L BM 42L EzStep MI 42L Ezi STEP MI 42XL BM 42XL EzStep MI 42XL Ezi STEP MI 42M BK Product Name User Code 20 20mm 28 28mm 42 42mm S...

Страница 8: ...r Speed Error Step Out Error Over Temperature Error Over Regenerated Voltage Error Motor Connect Error Motor Voltage Error System Error ROM Error LED Display Power Status Green Alarm Status Red CW Rot...

Страница 9: ...0 PERMISSIBLE OVERHUNG LOAD DISTANCE FROM END OF SHAFT 3mm N 18 18 30 30 30 22 22 22 22 8mm 30 30 38 38 38 26 26 26 26 13mm 53 53 53 33 33 33 33 18mm 46 46 46 46 PERMISSIBLE THRUST LOAD N Lower than m...

Страница 10: ...8 BM 20L 38 28mm Model name Length L BM 28S 32 BM 28M 45 BM 28L 50 A 4 16 0 1 20 0 5 L 1 1 5 0 2 7 0 2 10 0 5 0 075 0 025 A 0 075 4 M2DP2 5 16 0 05 3 5 0 1 0 4 0 012 0 A A 28 0 5 4 23 0 15 4 M2 5DP2 5...

Страница 11: ...jects 5 If you set more than 2 drives you must set over 20mm horizontally and over 50mm vertically as shown below PWR MOTOR ENCODER IN OUT PWR ALM PWR MOTOR ENCODER IN OUT PWR ALM PWR MOTOR ENCODER IN...

Страница 12: ...tion Lights when motor rotate CCW direction Protection functions and LED flash times Times Protection Conditions 1 Over Current Error The current through power devices in drive exceeds the limit value...

Страница 13: ...Direction setting switch ON Direction setting switch OFF 19 1 20 2 1 2 3 4 1 2 12 5 Pulse Input Setting Switch SW2 6 12 4 Rotational Direction Setting Switch SW2 5 Indication Switch Name Functions P P...

Страница 14: ...ilable to extended connection between motor and Ezi STEP MINI Item Length m Remark CMNB M F CMNB M M Normal Cable Robot Cable is for Cable Length The unit is 1m and Max 20m length Power Cable Availabl...

Страница 15: ...using Terminal PAP 04V S SPHD 001T P0 5 JST Motor Side Housing Terminal 5557 04R 5556T MOLEX Signal CN1 Housing Terminal 501646 2000 501648 1000 AWG 26 28 MOLEX 13 2 Connector Specifications Connector...

Страница 16: ...ny damages CAUTION Alarm Reset signal line is also used for Motor Free signal For details please refer to Control Signal Input Output Description When connects I O cable between controller and drive p...

Страница 17: ...ut Before cancel the Alarm output have to remove the source of alarm Caution If Alarm Reset input signal still remains ON motor will be Free state Keep in mind to change ON OFF state 1 Input Signal In...

Страница 18: ...om 18 Connector of Drive wiring Connector of Motor Pin layout Pin number Pin number Pin layout 1 2 3 4 1 3 4 2 3 1 4 2 1 2 3 4 Appendix Extension Cable for Motor For cable extension between Motor and...

Страница 19: ...www fastech motions com 19 MEMO...

Страница 20: ...or reproduced in whole or in part described in the User s Guide If you need a user manual to the loss or damage etc please contact us or your nearest distributor User manual are subject to change wit...

Отзывы: