-48-
•
Regenerative Resistor
Connecting to RG1, RG2 terminals when use a regenerative resistor
A regenerative resistor can be used when the deceleration time is short or when the large inertia
is driven by providing a regenerative resistor contact terminal.
Use a regenerative resistor of 100W/400ΩJ.
Attention
• Caution when a regenerative resistor wiring. It may cause electric shock.
7.3.2 Connecting the motor
Connect the motor connector (4pins) of the motor cable to CN2 and the sensor connector (6pins)
to CN3. Use optional relay cable when extending between motor and drive. Up to two cables can
be connected. The distance between the motor and drive can be extended up to 10m.
Attention
• Please surely connect connector to drive. If not perfectly connect connector, it
may cause poor movement or damaged of motor and drive.
7.3.3 Ground connection
Motor and drive are sure to ground with motor ground terminal and drive ground terminal. Drive
will may damage or malfunction due to static electricity.
Attention
• Motor and drive are sure to ground. It may cause damage and electric shock.
Drive will may damage or malfunction due to static electricity.
Содержание Ezi-SPEED ESD-120-C
Страница 1: ......
Страница 9: ...9 2 Characteristics 2 1 Part number...
Страница 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Страница 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Страница 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Страница 20: ...20 200W 400W...
Страница 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Страница 64: ...64 2 Input Output setting mode...
Страница 65: ...65 3 Parameter setting mode 1page...
Страница 66: ...66 3 Parameter setting mode 2page...
Страница 67: ...67 3 Parameter setting mode 3page...
Страница 68: ...68 3 Parameter setting mode 4page...
Страница 69: ...69 4 NVM saving mode...