![Fastech Ezi-SERVO ST Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/fastech/ezi-servo-st/ezi-servo-st_operation-manual_3577772029.webp)
www.fastech-motions.com - 29
Drive status LED
Direction setting
switch: ON
Direction setting
switch: OFF
16.4 Resolution Setting Switch(SW3)
*1 : Resolution of position
“
0
”
will be different according to the resolution of encoder adopted to the product.
But in case of the encoder with 10,000[ppr] resolution, it will be set as 500.
※ When selected resolution is more then encoder resolution, motor shall be operated by microstep between pulses.
The Number of pulse per revolution.
16.1 Drive Status LED
16.2 Pulse Input Setting Switch(SW1.1)
16.3 Rotational Direction Setting Switch(SW1.2)
◆ Protection functions and LED flash times
Indication Color
Function
ON/OFF Condition
PWR
Green Power input indication
LED is turned ON when power is applied
INP
Yellow Complete Positioning Motion
Lights On when Positioning error reaches within
the preset pulse selected by rotary switch
SON
Orange Servo On/Off Indication
Servo On: Lights On, Servo Off: Lights Off
ALM
Red
Alarm indication
Flash when protection function is activated
(Identifiable which protection mode is activated
by counting the blinking times)
Times
Protection
Conditions
1
Over Current Error
The current through power devices in inverter exceeds the limit value
*1
2
Over Speed Error
Motor speed exceeds 3,000 [rpm]
3
Position Tracking Error
Position error value is higher than 180˚ in motor run state
4
Over Load Error
The motor is continuously operated more than 5 seconds under
a load exceeding the max. torque
5
Over Temperature Error
Inside temperature of drive exceeds 85℃
6
Over Regenerative
Voltage Error
Back-EMF is higher than limit value
*2
7
Motor Connect Error
The power is ON without connection of the motor cable to drive
8
Encoder Connect Error
Cable connection error in Encoder connection of drive
10
In-Position Error
After operation is finished, position error more than 1 pulse is
continued for more than 3 seconds
11
System Error
Error occurs in drive system
12
ROM Error
Error occurs in parameter storage device(ROM)
15
Position Overflow Error
Position error value is higher than 180˚ in motor stop state
Alarm LED flash
(Ex, Position tracking error)
Indication
Switch Name
Functions
2P/1P
Selecting Pulse
Input Mode
Selectable 1-Pulse input mode or 2-Pulse input mode as Pulse input signal.
ON: 1-Pulse mode OFF: 2-Pulse mode
※ Default: 2-Pulse mode
Indication
Switch Name
Functions
DIR
Switching Rotational
Direction
Based on CW(+Dir signal) input to driver.
ON: CCW(-Direction) OFF: CW(+Direction)
※ Default: CW mode
Position
Pulse/Revolution
Position
Pulse/Revolution
0
500
*1
5
3,600
1
500
6
5,000
2
1,000
7
6,400
3
1,600
8
7,200
4
2,000
9
10,000
CW(Pulse) Pin
CCW(Dir) Pin
Rotational Direction
CW
CW
CCW
CCW
2-Pulse Mode
1-Pulse Mode
Motor
EzM-20~60 EzM-86
*1
Over Current
limit
4.8A
9.6A
*2
Over
Regeneratived
Voltage limit
70V
90V
Содержание Ezi-SERVO ST