Note - Store the block off plates in a safe place for future use.
15.
FREEZER MAINTENANCE DIVI
Viewing freezer temperature:
While in Vend Mode (indicated by “Please Insert Money” on the scrolling marquee on the Digital Display), press
the “*” key on the Customer Keypad. The current temperature will be displayed on the Digital Display.
Temperature Adjustment:
Depending on the freezer model, some machines have adjustable temperature controllers.
Standard Machines
If available, the temperature may be adjusted by turning the Thermostat Dial located on the
outside back of the freezer next to the left freezer lid hinge. The scale ranges from 1 which is the
warmest setting to 7 which is the coldest. The recommended factory setting is “5”. Three to four
hours after powering up the Vendor, the temperature inside the Freezer should drop to about
–
10°F / -23°C. The operating temperature for the standard ice cream and food vendor will vary
based on the prevailing temperature at the machine. Typically the operating range should be
between -5°F/-20°C and -15°F/-26°C.
Extreme Cold Machines
Extreme cold machines should reach operating temperature approximately 4 hours after being
turned on. Typically, operating temperature ranges between -30 °F / -34°C and -40°F / -40°C.
The temperature may be viewed by pressing the “*” key while in Vending Mode (Please Insert
Money).
Servicing the Freezer:
The standard chest freezer inside the DIVI does not self-defrost. The freezer chest requires maintenance when ice begins to affect the
vend cycle, product loading, or closing the freezer lid. The refrigeration system does not require any maintenance. Depending on the
location’s moisture level (relative humidity) and frequency of operation, ice may accumulate inside the Freezer above the level of the
bins.
FASTCORP recommends keeping the plastic ice scraper (pr
ovided with the machine), and a 9” by 11” piece of
cardboard or plastic inside the machine. Place the plastic under the area to be scraped to prevent the ice from
falling into the bins. This entire process should only take a few minutes. Wipe the area with a clean dry towel
after the frost has been removed. This process should be repeated each time the Vendor is serviced to prevent
large scale ice buildup that will require a time consuming freezer defrost.