6
Part #???
Revised ??????
Part # FAST4-207
Revised 6/16/14
FAST
™
3400 Democrat Rd.
Memphis, TN 38118
Phone: 901.260.3278
Toll Free: 1.877.334.8355
www.fuelairspark.com
Screen Disable
This button turns the screen blank. Touching anywhere on the screen will bring back the normal
display.
Live Data
The Live Data section of the hand-held consists of a series of dashes that display live ECU data.
To switch between dashes or to return to the home screen, use the tabs at the bottom of the screen. The
text will highlight green to indicate the current screen.
Across the top of every dash are 4 LEDs that indicate the following:
LABEL
DESCRIPTION
OFF
ON
Learning
This indicates that all of the enable conditions for
learning are met and that learning is currently
enabled. This can be used as feedback to give the
driver a feel for when the ECU will or will not learn.
Gray
Green
O2 On
The oxygen sensor has been initialized and is
providing feedback to the ECU. This must be ON
before closed loop fuel control is possible.
Gray
Green
Nitrous
The Power Adder Enable input has been
activated.
Gray
Green
Error
The ECU’s on-board diagnostics has detected a
problem. Refer to the Codes screen in the
Diagnostics section of the eDash to determine
what code has been set.
Gray
Red
Dash 1