PAGE 11
If using ACE PWM pump, change the coil frequency to 122.
Max Pump PWM:
Enter a maximum PWM duty cycle percent to set the maximum desired output for a
pulse width modulated (PWM) hydraulic control valve. This setting limits how far the
PWM valve will open.
(Typically set at 100 psi. deadhead.)
Min Pump PWM:
Enter a minimum PWM duty cycle percent to set the minimum desired output (zero point
or shutoff point) for a pulse width modulated (PWM) hydraulic control valve).
(Typically set at 20 psi. deadhead.)
PWM Standby:
Enter desired control valve PWM duty cycle percent when all sections are off. This is uti
-
lized when standby pressure control is not available (pressure sensor not available or
direct injection is installed).
(Typically set at within 10 psi of spray pressure.)
Press Next.
Содержание Raven RCM
Страница 2: ...80 600042 01 RAVEN RCM SETUP 2 18 2020...
Страница 4: ...PAGE 2 Leave at 1 unless multiple ECU s are used Press Next...
Страница 5: ...PAGE 3 Choose Application Mode FAST products only use Liquid Liquid choice selected Press Next...
Страница 8: ...PAGE 6 Not used unless there are special require ments Press Next...
Страница 9: ...PAGE 7 Section summary per product If using a switch box switch assignment is entered here Press Next...
Страница 10: ...PAGE 8 Choose pressure sensor if installed FAST only uses 0 250 psi Press Next...
Страница 11: ...PAGE 9 FAST does not use auxiliary functions leave unchecked Press Next...
Страница 12: ...PAGE 10 Standard control valve setup If machine has a PWM pump choose PWM PWM setup Press Next...
Страница 18: ...PAGE 16 Setup summary page Press Next...
Страница 19: ...PAGE 17 Not used For connecting to mobile app...
Страница 20: ...80 600042 01 RAVEN RCM SETUP 2 18 2020 NOTES...
Страница 21: ...80 600042 01 RAVEN RCM SETUP 2 18 2020...