background image

Page 8

Basic Operation

Humidity Control

NOTE:  Due to variations in environmental conditions, it is not always possible
to achieve the desired humidification or dehumidification setpoint. 

Press

HUMIDITY

To leave the Humidity Control screens. If no 
buttons are pressed, the display will leave the 
Humidity Control screens after 30 seconds.

Press the Humidity button
to enter Setup screens. 

Pages 18,20

HUMIDITY

Select On to energize
the humidifier system when
humidity drops below the
desired level.  Select Off
if no humidification is 
desired. 

ON

OFF

Adjust the desired 
humidification setpoint

(0%-60%)

ON

OFF

Adjust the desired 
dehumidification setpoint

(25%-99%)

NOTE:

 Each step # is located at

            the top right corner of the
            display for easy reference.

Press

Press

Press

Press

MODE

MODE

MODE

MODE

NOTE: If Humidity Step #1 is set to ON, you cannot set the Dehumidify setpoint 
any lower than the Humidify se 5%.  When both Humidity step #’s 1 and 
3 are set to ON, the adjustable 5% differential is forced between the Humidify 
and Dehumidify setpoints.

Current Room Humidity

45

   I

%

OFF

humidify

Select On to energize
the dehumidification 
system when humidity 
rises above the desired 
level.  Select Off if no 
dehumidification is desired. 

Current Room Humidity

Current Room Humidity

Current Room Humidity

  2

%

ON

25

humidify

45

  3

%

OFF

Dehumidify

45

  4

%

ON

Dehumidify

45

25

Step 3 appears if step 17 on page 16 is set to “ON”

Step 4 appears only if step 17 on page 16 is set to “ON”

Содержание 1 For All TR7DRH

Страница 1: ...t Meets Residential California Title 24 Mode Cooler Warmer International Comfort Products 2004 7 Day Programmable 4 Time Periods per Day Thermoglow Backlight One For All Technology Programmable Fan Se...

Страница 2: ...before proceeding SET THERMOSTAT TO MODE OFF PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS 9 13 18 23 Cool to Dehumidify Dehumidification Setpoint Dual Setpoint Behavior Electric...

Страница 3: ...or Button Mode Button Heat or Cool Indicator Red Heat Green Cool Mode Cooler Warmer Mode Cooler Warmer FAN OUTSIDE HUMIDITY PROGRAM SET CLOCK FAN OUTSIDE HUMIDITY PROGRAM SET CLOCK S E V E N D A Y P...

Страница 4: ...PROGRAM ON indicates the stored program is enabled to run Page 6 Clock with Day of the Week Indicates the current time and day This clock is also used to program the time periods Page 5 Room Temperat...

Страница 5: ...Service Filter and Service Pan Indication indicates when the filter should be serviced under normal conditions Appears after 0 1950 hours of blower operation adjustable Page 13 Service Pan indicates t...

Страница 6: ...the Clock and Go Page 5 This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming To optimize the installation of this thermostat fol...

Страница 7: ...g and air conditioning systems are turned off AUTO will automatically select heat or cool based on room temperature demand Program On will activate the stored timer operation Morning Day Evening Night...

Страница 8: ...mperature View Outdoor Temperature Fan Operation Page 7 Basic Operation Indicates constant fan operation This feature is active even if the thermostat is set to Off Press FAN Press Outside To view Out...

Страница 9: ...umidification setpoint 25 99 NOTE Each step is located at the top right corner of the display for easy reference Press Press Press Press MODE MODE MODE MODE NOTE If Humidity Step 1 is set to ON you ca...

Страница 10: ...time for Morning Adjust the heating setpoint for Morning Adjust the cooling setpoint for Morning M Su 35 99 35 99 Use the back cover Programming Worksheet to help with this section Press PROGRAM Press...

Страница 11: ...for Evening Adjust the start time for Day Adjust the heating setpoint for Day Adjust the cooling setpoint for Day 35 99 35 99 35 99 Press MODE Press MODE Press MODE Press MODE Press MODE Am 8 00 Day...

Страница 12: ...st the heating setpoint for Evening Adjust the cooling setpoint for Night Adjust the start time for Night 35 99 35 99 35 99 Press MODE Press MODE Press MODE Press MODE Pm 6 00 Evening M 78 COOL o 70 H...

Страница 13: ...ng mode will copy the previous day s program and then will ask the same copy question again If yes is selected each time this routine will repeat The copy command becomes available after programming t...

Страница 14: ...ck set section NOTE Each step is located at the top right corner of the display for easy reference PROGRAM MODE Press MODE Press MODE Press MODE Adjust the number of hours the blower will run before t...

Страница 15: ...g heating setpoints 0 6 Select the cycles per hour limit d cycles per hour limit defeated d1 d defeat 5 min Compressor lockout d d1 2 6 On Off Select ON for Standalone Humidity Fan operation Inteillis...

Страница 16: ...fan start time Step 16 appears only if step 15 is not 0 00 Adjust the programmable fan stop time Step 15 appears only if step 13 is not 0 00 Select the display back light always On or Off after 8 seco...

Страница 17: ...ppears if step 17 is set to ON Select Cool to Dehumidify feature Page 8 18 20 On Off Step 19 appears only if step 17 is set to ON Adjust the Maximum overshoot of the set temp In Cool to Dehumidify Mod...

Страница 18: ...0 1950 0 Heat Pump operation Off On Off 6 Reversing valve polarity O B O Electric Heat Off On Off 8 Deadband temperature swing 1 6 2 9 Heat Cool temperature difference 0 6 2 10 Cycles per hour d d1 2...

Страница 19: ...s 35 99 degrees in Fahrenheit and 2 36 degrees in Centi grade When in the modes Heat or Cool this adjustable range is unhampered When adjusting any Auto mode inclu ding programming 4 Time periods the...

Страница 20: ...read EH During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat when there demand for heat locking out the 1st stage compressor Exiting Emergency Heat is the same as enter...

Страница 21: ...nt ranges from 25 to 50 or OFF if no Humidity is desired or if a Humidification System has not been installed KEYPAD LOCK To prevent unauthorized use of the thermostat the front panel buttons may be d...

Страница 22: ...age turn on Cooling OUTDOOR SENSOR Optional Accessory When connected to terminals RS 5 RS1 RS GND on the back of the thermostat the thermostat will read the temperature from the outdoor not control to...

Страница 23: ...mable Fan timer will start the fan at the top of each hour The Programmable Fan may be active even if the thermostat mode is Off Steps 13 14 restrict the hours in which Programmable Fan may operate St...

Страница 24: ...RSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS AL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REM...

Страница 25: ...D A Y Morning Day Evening S U N D A Y Morning Day Evening Night T U R A S D A Y Morning Day Evening Night F R I D A Y Morning Day Evening Night Night W E N E S D D A Y Morning Day Evening Night T U E...

Отзывы: