4 -  EnergyCam 2.0  production defaults  

 

 

EnergyCam 2.0 Open Wire is configured by default as:

 

 

 

Gas 

 

wM-Bus: disabled 

 

Auto install after EnergyCam boot: enabled 

 

Read decimal: enabled 

 

Reading timer: 15 minutes 

 

Font: White on Black 

 

Modbus, 115200 baud, 8E1 

 

Slave address: 1 

 

– Wire assignment 

The assignment of the 4-wire cable is as follows: 

 

 

RED

: 3.3-3.6 VDC / 

≥ 100 mA 

 

GREEN

: EnergyCam-RxD TTL 

 

YELLOW

: EnergyCam-TxD TTL 

 

BLACK

: GND 

 

IMPORTANT: There is no polarity protection. Interchanging red and black will damage the device! 

 