Step 2:
Mounting the FASS
Some of the photo’s are of a different application, procedures are the same.
D.
Position system where it will be mounted. Mark the (4) mounting points (
using the template located on
the contents page
). Prior holes may be used. Dr ill these marked locations with a 13/32 bit.
G.
Apply motor oil to O-rings located on filters. Attach to system and tighten appropriately
E.
Connect factory plug into the FASS harness. Turn key to “on”. With pump operating, turn pump over,
liberally spray WD-40 (or equivalent) into water separator nipple lubricating the Gerotor.
F.
Assemble to frame using the (4) - 3/8” bolts & flange nuts placing the RS-1001 between the frame and
bracket. An optional accessory is SFB-1001.
Note: O-Ring must be put back on suction side of pump. Failure to do so can result in
priming issues, cavitation, or pressure loses.
Before starting installation please review contents page to insure all necessary parts are included. Please
call Diesel Performance Products for any missing or incorrect items. 636-433-5410
Содержание T 095G