4.2
How to control the calibration of Wheel Balancer
Press<+/-> to select
CAL TEST
Place a wheel on the flange (see the picture 11).
Hand spin the wheel
Put the calibration weight as shown in the picture
12.
Hand spin the wheel
Press
<FINE>
to see actual values. 160-0 (±3)
is correct result
When all LED (left side) are lit, calibration weight
must be at exactly 6 o’clock.
If no, press
<FUNC>
to calibrate position
Turn the wheel until the calibration weight is
located at 6 o’clock.
Press
<SET>
to calibrate the position.
Press
<MODE/ESC>
to return to normal
balancing mode